Why designers hop between bar and MPa

European valve catalogs rate their products by nominal pressure in bar, and international design standards and finite element programs work in megapascals. The same pipe schedule can therefore appear as PN 16 on a purchase order and as 1.6 MPa on a stress calculation. The two units are connected by a plain factor of 10, which is easy enough to apply once and easy to drop in a long table. This page converts bar to megapascals with MPa = bar × 0.1. The default 10 bar gives 1 MPa. It also includes pascals, kilopascals, psi, atmospheres, millibars, torr, millimeters and inches of mercury, millipascals and micropascals, so any intermediate step is available. Both units are decimal and exact with respect to the pascal, so the conversion carries no rounding other than the digits that you choose to show.

Definitions

The bar is defined as exactly 100,000 Pa. It is not an SI unit, but the BIPM SI Brochure lists it among the non-SI units that remain in use. The megapascal is 10^6 Pa, a standard SI prefix multiple of the pascal. So 1 bar is 0.1 MPa and 1 MPa is 10 bar. The word bar comes from the Greek for weight, and the unit was introduced in early 20th-century meteorology, chosen to be close to the average atmospheric pressure of about 1.013 bar. In engineering, a handy equivalence is that 1 MPa equals 1 newton per square millimeter, which is the unit of stress used for material strength. This is the reason MPa is common in mechanical design: pressure and stress share a unit, so a pressure can be compared directly with a yield strength.

Nominal pressure ratings

In Europe, pipes, flanges and valves are classified by PN numbers, where PN stands for nominal pressure. A PN 16 component is designed for a nominal 16 bar at a reference temperature, which equals 1.6 MPa. PN 10 is 1 MPa, PN 25 is 2.5 MPa, and PN 40 is 4 MPa. The allowable pressure falls as temperature rises, according to the material and the standard, so the PN label is a class rather than a guarantee at any temperature. A design drawing in MPa and a catalog in bar can be reconciled through this page. Enter 16 bar and the answer is 1.6 MPa. Check the actual pressure-temperature rating in the product standard before relying on the label, since the conversion does not change the allowable pressure at your operating temperature.

Hydraulics and gas storage

Hydraulic power units are often specified in bar, with typical system pressures of 100 to 350 bar. That equals 10 to 35 MPa. A mobile machine with a 350 bar relief setting runs at 35 MPa, which is 35 newtons on every square millimeter of surface. Compressed gas cylinders are filled to 200 or 300 bar, which is 20 or 30 MPa. Scuba cylinders at 200 bar are 20 MPa, which is about 2,900 psi. Water mains operate at 3 to 6 bar, or 0.3 to 0.6 MPa, and household supply is regulated to 2 to 4 bar. A pressure washer at 150 bar is 15 MPa. Expressing these in MPa shows the span between a domestic tap and a hydraulic press more cleanly, since the numbers become 0.3 and 35 instead of 3 and 350.

Worked examples

Convert a hydraulic press setting of 350 bar. The answer is 350 × 0.1 = 35 MPa. For a cylinder rated at 232 bar, which is a common scuba working pressure, the result is 23.2 MPa. A boiler safety valve set at 16 bar corresponds to 1.6 MPa. In the reverse direction, a design pressure of 0.6 MPa is 6 bar, a test pressure of 2.4 MPa is 24 bar, and a vacuum pump specification of 0.001 MPa is 0.01 bar, or 10 mbar. These are illustrative values that test the arithmetic. When you are converting a test pressure that is 1.5 times the design pressure, convert each separately rather than scaling a rounded conversion, so that 16 bar design pressure gives 1.6 MPa and 24 bar test pressure gives 2.4 MPa, with no accumulated rounding.

Gauge, absolute and differential

Bar and MPa are used for all three pressure references, and converting the unit does not change the reference. A tank labeled 10 bar gauge is 1 MPa gauge, and about 1.1 MPa absolute at sea level, since atmospheric pressure is about 0.1 MPa. Vessel codes normally use gauge pressure for design, and thermodynamic tables use absolute pressure. Labels such as barg, bara and barD (differential) exist, and the SI does not allow adding a letter to the unit symbol, but in practice the suffixes carry necessary information. When you convert 10 barg, write 1 MPa (gauge). If a document writes only bar, check the context. For vacuum, absolute pressure in bar is below 1, and the corresponding MPa value is below 0.1. A mistake of one atmosphere, 0.1 MPa, is big at low pressure and small at high pressure.

Bar, psi and the United States

American practice uses psi for pressure, and an engineer reading a European data sheet in bar usually wants psi. This page lists psi, so you can convert 10 bar directly. As a mental route, 1 bar is about 14.504 psi and 1 MPa is about 145.04 psi. A 10 bar line is therefore about 145 psi, and a 35 MPa system is about 5,076 psi. The exact definition behind psi is the pound-force per square inch, which is 6,894.757... Pa. Keep a note of whether a quoted psi is gauge (psig) or absolute (psia). In the US, ASME pressure vessel codes accept SI units, and many drawings show both. Round the converted figure to the same number of significant digits as the original, since 145 psi implies more precision than a nominal 10 bar.

Significant figures and rounding

The factor of 0.1 does not change the number of significant digits, only the position of the decimal point. A pressure of 10 bar, with two significant digits, becomes 1.0 MPa, and 16 bar becomes 1.6 MPa. Do not drop a trailing zero if it is significant. A test pressure of 24.0 bar is 2.40 MPa. For pressure ratings, rounding down is the conservative direction when the value is a limit, and rounding up is the conservative direction when the value is a load. Because the conversion is exact, you can usually avoid rounding altogether by keeping the digits. Reserve rounding for the final presentation, and use the exact converted figure for any subsequent calculation.

Limits of the conversion

The page changes the unit of a pressure value. It assumes the number is a valid pressure with a known reference, and it does not calculate installation limits, equipment ratings, protection, material response or compliance. It does not check whether a pressure is suitable for a pipe, vessel, hose, valve or cylinder, and it does not model temperature derating, fatigue, corrosion or test requirements. Pressure equipment is governed by codes and by the manufacturer's ratings, and work on pressurized systems should be done by qualified people. Use the converter to read a rating in the unit your calculation needs, then verify the rating against the original document.

Everyday pressures for scale

Common pressures give a feel for the numbers. A road bicycle tire at 7 bar is 0.7 MPa. A car tire at 2.4 bar is 0.24 MPa. An espresso machine pump brews at about 9 bar, which is 0.9 MPa. A household water supply of 4 bar is 0.4 MPa. A compressed air workshop line at 8 bar is 0.8 MPa. Industrial hydraulic systems at 250 bar are 25 MPa. Atmospheric pressure is 1.013 bar, or 0.1013 MPa. Reading across the list, most consumer pressures are below 1 MPa and most hydraulics are above 10 MPa, which is why MPa feels like the natural unit for heavy equipment and bar for everyday items. The converter lets you move between the two vocabularies while the physical pressure stays the same. These figures are typical values for illustration, and the label on a given product is the authority.

Pressure, force and wall stress

The reason MPa is popular in mechanical design is that it equals one newton per square millimeter, so force and stress calculations come out in newtons without extra factors. A hydraulic cylinder with a piston diameter of 50 mm has an area of 1,963.5 mm². At 35 MPa, which is 350 bar, it pushes with 35 × 1,963.5 = 68,722 N, about 68.7 kN. In bar, the same calculation needs the factor of 0.1 to get N/mm². For a thin-walled pipe, the hoop stress is approximately pressure times diameter divided by twice the wall thickness. At 1.6 MPa (16 bar) in a pipe of 100 mm diameter and 3 mm wall, that gives 1.6 × 100 / 6 = 26.7 MPa. This is an illustration of the arithmetic and not a design method. Real design adds allowances, joint factors and safety factors from the applicable code.

Writing the unit clearly

A few conventions prevent misreading. The symbol for megapascal is MPa, with capital M and capital P, and the symbol for bar is bar, lowercase and not abbreviated. A lowercase mpa is not a valid symbol. Leave a space between number and unit, as in 1.6 MPa. Use a decimal point or comma consistently with the rest of the document. In mixed documents, state both values once, for example 16 bar (1.6 MPa), then keep to one unit. When a drawing is used by teams in different regions, a note with the conversion factor, 1 MPa = 10 bar, prevents a slip of a decimal place. Tables that mix the two units in adjacent columns invite mistakes, so label the headers and keep one unit per column.