Vacuum gauges and pascal-based controllers

Rotary evaporators, vacuum ovens, freeze dryers and filtration pumps often come with gauges in mmHg or torr, while the sensor datasheet or the control software of the same machine reports in pascals, millibar or millipascals. At low pressure the millipascal is a convenient unit, because levels near 0.1 Pa become readable numbers instead of long decimals. This page multiplies the mmHg value by 133,322.387415 and returns millipascals, so a setpoint written for one scale can be entered on the other. A technician comparing a pump curve with a chamber reading, or a student reading a method written in mmHg, can match the numbers without searching for a table.

The factor behind the page

The conventional millimeter of mercury is defined from a mercury density of 13,595.1 kg/m³ and standard gravity 9.80665 m/s². The product with 0.001 m is 133.322387415 Pa, the number used here at 0 °C. One millipascal is 0.001 Pa, so the conversion multiplies by 1,000 more: 1 mmHg is 133,322.387415 mPa. The torr, defined as 1/760 of a standard atmosphere, is 133.322368 Pa, which differs from the mmHg by about 0.00001 percent, so a gauge marked in torr can be treated the same way. The pascal is the SI unit, one newton per square meter, and the prefix milli makes it a thousandth of that.

Ten mmHg in millipascals

The default of 10 mmHg gives 1,333,223.87415 mPa, which is 1,333.22 Pa. A more usual low-pressure value, 0.1 mmHg, equals 13,332.24 mPa, or 13.33 Pa. At 100 mmHg the answer is 13,332,238.74 mPa, about 13.3 kPa. The longest number comes from atmospheric pressure: 760 mmHg is about 101,325,014 mPa. Compare each result with the input, which should be about 133,000 times smaller. A result near the input, or one that is a million times larger, signals that a unit was changed by mistake. The page shows the figure with the digits of the engine, so round it to the resolution of your gauge before it goes into a record.

Freeze dryers and the millitorr habit

Home and lab freeze dryers show vacuum in millitorr, and a typical target is a few hundred millitorr, which is a few tenths of a mmHg. Since one millitorr is about 0.001 mmHg, 500 mTorr is about 0.5 mmHg, which the page converts to about 66,661 mPa, or 66.7 Pa. That is roughly 0.0007 of an atmosphere. If a machine manual quotes its limit in pascals and you read a gauge in millitorr, divide or multiply through mmHg as done here. The numbers are illustrative of how such a unit is read, so follow the manual of your own equipment for the target, because it depends on the product and on the design of the machine.

Rotary evaporators and solvent boiling points

Chemistry methods often give the vacuum for a rotary evaporator in mmHg or mbar, since lowering the pressure lowers the boiling point of the solvent. A published setting of 100 mmHg corresponds to about 13,332,239 mPa, or 133 mbar, and a controller that works in pascals wants 13,332 Pa. Typing the wrong unit into a controller can pull a much stronger vacuum than the method intended and make a solvent boil over. The converter helps you move the setting between sources. It cannot tell you which pressure is right for a solvent and bath temperature, which comes from a vapor pressure chart or from the method itself.

Going back from millipascals to mmHg

For the reverse direction, select millipascals as the source and mmHg as the target. A reading of 133,322.387415 mPa is 1 mmHg, and 1,000 mPa, which is 1 Pa, is about 0.0075 mmHg, or 7.5 millitorr. Low pressures in pascals give small mmHg numbers, so the exponent form is easier to copy. A pressure sensor that reads 50 mPa corresponds to about 0.000375 mmHg, which is 0.375 millitorr, a level only a good pumping system reaches. Comparing the two views helps you judge whether a number from a datasheet sits in the rough, medium or high vacuum range.

Absolute versus gauge readings

Many cheap vacuum gauges show how far the pressure is below the surrounding atmosphere, not the absolute pressure inside the chamber. A gauge reading of minus 700 mmHg means about 60 mmHg absolute when the atmosphere is 760 mmHg, which is 8,000 Pa. The page converts a number to a number and cannot tell which kind you entered, so convert the absolute value when you compare with a datasheet. Subtract the gauge reading from the local atmospheric reading first, then convert. Weather and altitude change the atmospheric part by several percent, enough to matter when the target is a low absolute pressure. At a site 1,500 meters above sea level the atmosphere is closer to 635 mmHg than 760, so the same minus 700 reading would be physically impossible there.

Vacuum sealers, degassing and pump ratings

Pump makers rate a vacuum pump by its ultimate pressure, often in mmHg, torr or pascals, and by its pumping speed. A diaphragm pump that reaches 75 mmHg absolute is about 10,000 Pa, or 10,000,000 mPa after conversion, which is a rough vacuum good for filtration and solvent removal. An oil-sealed rotary vane pump that reaches 0.01 mmHg is about 1.33 Pa, or 1,333 mPa. The two numbers differ by a factor of 7,500, which is the real gap between the machines. Chamber volume, hose length and leaks keep the working pressure above the rating on the label. Use the page to line up specifications on one scale, and read the pump curves for what the setup will do. If two catalogs list the same pump, one in mmHg and one in pascals, converting both to millipascals shows quickly whether the figures describe the same performance or different test conditions, such as a blanked-off inlet versus a stated flow.

Precision and limits

The factor carries more digits than any gauge. Thermocouple and Pirani gauges are accurate to a few percent at best in the middle of their range and far worse at the ends, so two significant digits are usually plenty. The page changes a unit and does not calibrate an instrument, check the vacuum rating of glassware or judge whether a setup is safe. Evacuated glass can implode, and rating and safety rules come from the manufacturer and your lab. Use the converter for consistent numbers and the manuals for decisions.