Small pressures in building and airflow work

Differential pressure sensors in ventilation ducts, cleanrooms and fume cupboards, draft gauges on boilers and low-speed airflow probes all report in single pascals or fractions of one. Some of them output millipascals, and a technician commissioning a system has to translate those readings into the pascal values that appear in a design specification. This page divides the millipascal figure by 1,000 and returns pascals. It suits HVAC commissioning, lab technicians checking room pressure, students working with pitot tubes and anyone who reads a sensor data sheet where the fine-resolution column is given in mPa. The conversion is a shift of three decimal places and is easy to do by hand, but errors creep in when a long column of readings is converted.

Milli means a thousandth

The pascal is the SI unit of pressure, defined as one newton per square meter. The prefix milli means 10^-3, so 1 mPa is 0.001 Pa and 1,000 mPa is 1 Pa. NIST SP 811 and the BIPM SI Brochure list both. The factor is defined, and the conversion does not introduce any uncertainty. Pay attention to the symbol. The lowercase m before Pa means milli. A capital M would mean mega, so MPa is a million pascals, a unit for the strength of materials and hydraulic pressure rather than airflow. Mixing the two changes the result by a factor of a billion. Keep the case exactly as printed on the sensor sheet.

Ten millipascals as pascals

The default of 10 mPa returns 0.01 Pa. Other values: 250 mPa is 0.25 Pa, 1,500 mPa is 1.5 Pa and 12,500 mPa is 12.5 Pa. The number in pascals is always smaller than the number in millipascals, because the pascal is the larger unit. If the result is bigger than your input, the from and to menus are swapped. Reading values in groups helps: 12,500 mPa splits into 12 Pa and 500 mPa, which is 12.5 Pa. For the default, the result is a hundredth of a pascal, which is below the resolution of most building pressure sensors and sits in the range of laboratory micro-manometers and research-grade transducers.

A sheet of paper and a gentle breeze

To get a feel for the size of a millipascal, take an A4 sheet of 80 g/m² paper lying flat. Its weight spreads over its area to give a pressure of 0.08 kg/m² times 9.80665 m/s², about 0.7845 Pa, which is 784.5 mPa. A wind of 1 m/s in air of density 1.225 kg/m³ has a dynamic pressure of half the density times the speed squared, which is 0.6125 Pa or 612.5 mPa. At 10 m/s the same formula gives 61.25 Pa. These are illustrative calculations with the standard sea-level density of air, and real air density varies with temperature and altitude. They show that a sensor with millipascal resolution can follow very slow air movement.

Cleanrooms, fume cupboards and chimneys

Rooms where air must flow in a controlled direction are held at a small pressure difference from their neighbors. Guidance for pharmaceutical cleanrooms commonly cites differences of 10 to 15 Pa between adjacent areas of different classification. Sensors on those doors report in pascals, and an alarm may be set at a value such as 5 Pa. A drift of 500 mPa, which is 0.5 Pa, is a tenth of that alarm margin, so an instrument log that lists readings in millipascals reveals drift early. A chimney or flue draft of roughly 10 to 25 Pa below room pressure is also common for domestic boilers, and installers read it with a manometer. Check the limits in the documents for your own equipment and the rules of your country.

Pitot tubes and wind speed

A pitot tube measures dynamic pressure, from which speed follows as the square root of twice the pressure divided by the air density. A reading of 0.6125 Pa, equal to 612.5 mPa, corresponds to 1 m/s at the standard density of 1.225 kg/m³. A sensor with a noise level of 50 mPa therefore limits the lowest speed that can be resolved, and for slow airflow in a duct or a wind tunnel the noise figure can matter more than the full-scale range. Data sheets sometimes list the offset drift in millipascals per degree. Converting such figures to pascals gives a feel for how the zero shifts when the room warms by several degrees during a test.

Pascals back to millipascals

To convert the other way, choose pascals as the source and millipascals as the target. The page multiplies by 1,000. A pressure of 0.25 Pa is 250 mPa, 12.5 Pa is 12,500 mPa and 0.7845 Pa is 784.5 mPa. When you are logging data, keep one unit through the whole spreadsheet. Mixing pascals and millipascals in a single column is a common source of silent errors, since a value of 12.5 looks fine whichever unit it is in. Add the unit to the column heading and, if the sensor outputs raw counts, convert once at the import step so that all later calculations use the same unit.

Reading sensor data sheets

Data sheets for low-range differential pressure sensors list several figures that are easy to confuse. Full scale is the largest pressure the sensor reports, for example 250 Pa. Resolution is the smallest step the output can show, and it may be given as 1 mPa or as a fraction of full scale. Accuracy covers offset, gain and temperature error, and it is usually several orders of magnitude worse than the resolution. Noise is the random scatter of a still reading. When you convert any of these to pascals, keep the label, because a resolution of 10 mPa and an accuracy of 10 mPa describe very different capabilities. A sensor that resolves 10 mPa but drifts by 1 Pa with temperature needs a zero adjustment before each test.

A prefix change, not a pressure analysis

The page changes the unit of a pressure value. It does not check whether a room meets a pressure requirement, calibrate a sensor, correct for air density or tell you whether a reading is gauge, differential or absolute. Keep that label with the number. For commissioning and compliance, use the specifications of your project and the manuals of your instruments, and have the work done by qualified people.