Why vacuum work keeps the torr alive
The torr is not an SI unit, yet vacuum gauges, pump specifications and many laboratory protocols still quote it. Equipment from the United States and from older catalogs lists ultimate pressure in torr or millitorr, while newer instruments and papers use pascals. Micropascals appear when a writer wants whole numbers at high vacuum. This page connects the three. Enter a micropascal figure and read the torr value you can compare with a gauge or a pump curve. The conversion is a pure unit change with no assumptions about gas type, temperature or the instrument that produced the number.
Deriving the factor from 1/760 atmosphere
The standard atmosphere is 101,325 Pa exactly, and one torr is 1/760 of that, which is 133.322368421 Pa. The relationship in micropascals follows from the micro prefix. One torr equals about 1.33322 × 10^8 µPa, and one µPa equals 7.50061682704e-9 Torr. The default 10 µPa gives 7.5006e-8 Torr. NIST SP 811 states the torr in the same way, as 101,325/760 pascals. Because the definition uses whole numbers, the factor has no measurement uncertainty. Only the digits of the division are rounded for display. A useful memory aid is that 1 Pa is a little over 7.5 millitorr.
A home freeze dryer at 500 millitorr
Home freeze dryers commonly show the chamber vacuum in millitorr, and cycle instructions refer to values in the hundreds of mTorr. A reading of 500 mTorr is 0.5 Torr, which equals 66.66 Pa or about 6.666 × 10^7 µPa. A reading of 100 mTorr is 0.1 Torr, or 13.33 Pa. Entering 0.5 with torr as the source and micropascals as the target returns 66,661,184 µPa. The unit is the only thing the page changes. How low a pressure the cycle needs depends on the machine and the food, so follow the manual for targets. The converter helps when a published guide gives the pump spec in pascals and your display shows millitorr.
Laboratory vacuum and sensor ranges
Rough vacuum pumps in research labs reach about 10^-3 Torr, which is 0.133 Pa or 133,322 µPa. Turbomolecular pump systems list base pressures of 10^-6 Torr or lower, equal to about 133 µPa. At 10^-9 Torr the pressure is roughly 0.13 µPa. Gauge manufacturers publish the ranges of their sensors in torr, so a spec such as 10^-4 to 760 Torr covers about seven orders of magnitude. Converting a few points to micropascals shows the scale of the lowest readings and helps when comparing with literature that uses SI units. Remember that these pressures are absolute and differ from gauge readings that are relative to the atmosphere.
Torr compared with mmHg
The torr and the conventional millimeter of mercury are nearly the same size. One torr is 133.322368 Pa, and one conventional mmHg is 133.322387 Pa. The difference is about 0.000014 percent, much smaller than any gauge error. Blood pressure and vacuum use the two names for different fields, but the numbers agree for practical purposes. If you need the strictly conventional mercury value, use the mmHg converter, and if your source says torr, stay with this one. A standard atmosphere is 760 of either unit, which is 101,325 Pa, or 1.01325 × 10^11 µPa.
Prefixes: millitorr and microtorr
Vacuum documents use mTorr for millitorr and µTorr for microtorr, and these prefixes are easy to mix up with the micropascal. The page does not have millitorr or microtorr as separate units, so convert them first. 500 mTorr is 0.5 Torr, and 2 µTorr is 0.000002 Torr. Then enter the torr value and read the micropascal result. One Torr is 1.33322 × 10^8 µPa, so one µTorr is 133.322 µPa and one mTorr is 133,322 µPa. Writing the numbers out before you enter them avoids slips of three orders of magnitude.
Going from torr to micropascals
Choose torr as the source and micropascals as the target to multiply by about 1.33322 × 10^8. One Torr becomes 133,322,368 µPa. A pressure of 760 Torr becomes 1.01325 × 10^11 µPa. A pressure of 1 mTorr, entered as 0.001 Torr, becomes about 133,322 µPa. The reverse is useful when you are building a table of pump performance in SI units from a catalog in torr. Rounding to four significant digits is enough for most documents, since vacuum gauges are rarely accurate to better than a few percent of reading, and some are only good to a factor of two at the lowest range. If you keep a log of pump-down runs, store the pressure in pascals with the torr value beside it, so that later comparisons with SI-based literature need no further arithmetic and nobody has to guess which unit a column used.
Evacuating an air conditioning system
Technicians who service refrigeration and air conditioning systems pull a vacuum before charging, and their micron gauges read in microns of mercury. A micron here equals one millitorr, so a target of 500 microns is 0.5 Torr, which is 66.66 Pa or about 6.666 × 10^7 µPa. A deeper reading of 250 microns is 0.25 Torr, or 33.33 Pa. The usual practice is to isolate the pump and watch whether the reading rises. A fast rise points to a leak or to moisture still boiling off. The unit name causes confusion, because micron here has nothing to do with micropascals. The converter turns the figure into pascals when an equipment specification uses SI units. Follow the procedure in the manufacturer's service manual for the target value and the hold time.
What the converted pressure does not tell you
The page converts a pressure unit. It does not tell you whether a vacuum is deep enough for a process, whether a chamber can withstand it or whether a gauge is trustworthy at that level. Thermal gauges depend on the gas, and their readings can be wrong by large factors for gases other than the one they were calibrated with. The page does not calculate installation limits, equipment ratings, protection, material response or compliance. Glass vessels under vacuum can implode, so follow the equipment manual for rated pressures and protective measures, and use a converted figure only to compare numbers between documents. Record the gauge type with every reading, since a thermal gauge and a capacitance gauge can disagree at the same true pressure, and say which unit the gauge displayed before you converted it.