US gauges and metric sensor data

In the United States, pressure gauges for water systems, compressors, tires and pressure cookers show psi. Sensor datasheets and scientific instruments use pascals and its prefixes. Micropascals appear when an engineer writes the resolution or noise of a sensor, or when an analysis tool reports pressure in SI units. This page converts the micropascal figure into the psi that a gauge shows, so you can see how fine a sensor is relative to the markings on a dial. It makes the comparison concrete, because a gauge rarely resolves better than 1 psi, while the sensor behind a digital readout may resolve millionths of that.

Defining the pound per square inch

The psi is defined from the pound-force and the inch. With 1 lbf = 4.4482216152605 N and 1 in = 0.0254 m exactly, 1 psi = 6,894.757293168 Pa, a value NIST SP 811 lists. The conversion from micropascals follows. One psi is about 6.894757 × 10^9 µPa, so one µPa is 1.4503773773e-10 psi. The default 10 µPa gives 1.4504e-9 psi. Because the factor comes from exact definitions of the pound and the inch, you can trust all printed digits. The only limit is how many digits a sensor can really resolve, which is why the result is best rounded for reports.

Household water pressure at 60 psi

Municipal water supplies in the US commonly deliver between 40 and 80 psi at the house, and many plumbing codes call for a pressure reducing valve when static pressure exceeds 80 psi. A home with a reading of 60 psi has a water pressure of 413,685 Pa, which is about 4.1369 × 10^11 µPa. A pressure of 80 psi is 551,581 Pa, or about 5.5158 × 10^11 µPa. Gauges that screw onto a hose bib show the value, and they are accurate to a few psi. Expressing the reading in micropascals is not common in plumbing, but the conversion helps when you log data from a digital transducer with an SI output.

Air tools and compressor tanks

A pneumatic nailer is typically specified to run at around 70 to 120 psi, and a compressor regulator is often set near 90 psi. A pressure of 90 psi equals 620,528 Pa, which is about 6.2053 × 10^11 µPa. A compressor tank may be rated for 125 psi or more, and the rating is printed on the tank. Pressure transducers for these systems have a resolution that depends on their range, and a transducer with a 0 to 200 psi span and a resolution of 0.001 psi resolves about 6.895 × 10^6 µPa. Seeing that figure in micropascals tells you how fine the signal chain is, even though a person reading a dial would never notice it.

Gauge psi and absolute psi

US gauges often show psig, pressure above the surrounding atmosphere, while an absolute reading is psia. Atmospheric pressure at sea level is about 14.696 psia. A tank that reads 60 psig holds about 74.7 psia. The converter changes the unit and not the reference, so entering a gauge value gives a gauge value in micropascals. If your micropascal figure comes from a sensor that measures absolute pressure, subtract the atmosphere before comparing it with a gauge. A sealed absolute sensor in a room at standard pressure reads about 1.01325 × 10^11 µPa even when a gauge reads zero. Confusing the two is a common cause of apparent offsets in logged data.

Psi, kPa and bar equivalents

A few equivalents help catch mistakes. One psi is 6.894757 kPa, and 14.504 psi make one bar. A reading of 60 psi equals about 4.137 bar, and 100 psi equals about 6.895 bar or 689.5 kPa. When a datasheet lists a range in bar and your gauge is in psi, a quick estimate is to multiply bar by 14.5. These shortcuts are accurate to within a fraction of a percent, but the page uses the full factor. If your result differs from the shortcut by more than a few percent, the wrong unit probably was selected, and you should check the dropdowns.

Going from psi to micropascals

Set pounds per square inch as the source and micropascals as the target to multiply by 6.894757293 × 10^9. A pressure of 1 psi becomes 6,894,757,293 µPa, and 14.696 psi becomes about 1.01325 × 10^11 µPa. A water pressure of 60 psi becomes about 4.1369 × 10^11 µPa. This direction is useful when an analysis script expects SI units and your source is a US gauge or manual. The page prints the result with several significant digits, but a household gauge only supports two or three. Round the answer to the precision of your instrument before you use it in a report.

Transducer accuracy stated as a share of full scale

Pressure transducers state accuracy as a percentage of full scale. Take a sensor with a 0 to 100 psi range and an accuracy of 0.25 percent of full scale, used here as an illustration. The allowed error is 0.25 psi, which is about 1.724 × 10^9 µPa, at any point in the range. At a reading of 5 psi, that error is 5 percent of the reading, so the sensor is a poor choice for low pressures. A 12-bit converter splits the same range into 4,096 steps of about 0.0244 psi, or 1.683 × 10^8 µPa. Putting these values into one unit shows whether the sensor, the converter or the display limits the precision. Check the datasheet for the exact definition, since some manufacturers state accuracy against the reading instead.

What the conversion cannot assess

The page converts pressure units. It does not check that a gauge is accurate, that a hose or tank is rated for a pressure, or that a plumbing system complies with code. The working pressure stamped on a hose, tank or relief valve is what you check separately. For compressed air and water systems, follow the manufacturer's ratings and the codes that apply in your area, and use a qualified person for work on pressurized systems. A converted number should never be the only basis for deciding that equipment is safe to operate at a given pressure. Pressure relief valves, hose ratings and tank certifications exist for that purpose, and they are read from the labels on the equipment itself. If a label is missing or unreadable, treat the equipment as unrated and contact the manufacturer, since a conversion cannot supply the missing rating.