A barometer reading meets a sensor datasheet

US weather reports and home barometers show pressure in inches of mercury, with values around 29 to 31 inHg. Sensor datasheets for the chips inside weather stations and phones list resolution, noise and accuracy in pascals or smaller units. When you compare the two, you need a common unit. This page turns a micropascal figure into inHg so that a noise specification of a few hundred thousand micropascals can be read against the scale of the barometer on the wall. It also works the other way around, converting a reading in inHg to micropascals for software that stores pressure in SI units. The page uses the conventional inch of mercury at 0 °C, which is the definition behind the factor.

The factor and the 0 °C definition

The conventional inch of mercury is based on a mercury density of 13,595.1 kg/m³ and standard gravity of 9.80665 m/s², which gives 3,386.389 Pa per inHg. NIST SP 811 lists inches of mercury at 32 °F as 3,386.389 Pa, and a separate value near 3,376.85 Pa for mercury at 60 °F. The page uses the 0 °C figure, so inHg = µPa × 2.9529983301e-10. With the default 10 µPa the result is about 2.953e-9 inHg. The temperature in the definition refers to the mercury in a mercury column instrument. An electronic sensor does not depend on it, because the reading is in pascals before conversion.

One pascal of resolution on the barometer scale

A pressure sensor with a resolution of 1 Pa can distinguish changes of 1,000,000 µPa. Entering that number gives about 0.0002953 inHg. A household barometer with a dial marked in hundredths of an inch cannot show such a change, since 0.01 inHg is about 33.9 Pa. That explains why a digital station reports small trends that an analog dial hides. If a datasheet lists a noise level of 0.5 Pa RMS, you can convert 500,000 µPa and see that the noise equals about 0.000148 inHg, far below the last digit of a typical display. The conversion makes it clear which part of the sensor performance a user would actually notice.

Everyday readings in micropascals

A standard atmosphere is 101,325 Pa, which equals 29.9213 inHg. In micropascals it is 1.01325 × 10^11 µPa. A reading of 29.92 inHg corresponds to about 1.0132 × 10^11 µPa, and a reading of 30.00 inHg to about 1.0159 × 10^11 µPa. A fall from 30.00 to 29.50 inHg is 0.50 inHg, or about 1,693 Pa. Forecasters watch such a change over several hours as a sign of weather shifting. When you enter a barometer value as the source and micropascals as the target, the digits that matter for comparison are the leading ones, since a household instrument is accurate only to a few hundredths of an inch.

Differences matter more than absolute values

Small barometric changes are more informative than a single reading. If your station logs pressure in micropascals, subtract two readings first and convert the difference. A change of 338,639,000 µPa is 338.6 Pa, or 0.1 inHg. Working with differences cancels calibration offsets, which are common in low-cost sensors. When you convert only the difference, the factor stays the same, and the result shows how far the pressure moved on the familiar inHg scale. Compare it with the trend lines you see in a forecast to judge whether a sensor behaves sensibly over a day.

Mercury inches, millimeters and other readers

The inch of mercury and the millimeter of mercury describe the same kind of column. One inHg is 25.4 mmHg by length, and in the conventional definitions 3,386.389 Pa corresponds to 25.4 times 133.322387 Pa, within rounding. If a source gives millimeters of mercury, convert it with the mmHg option instead of re-deriving the factor. Some US sources use hectopascals or millibars for the same pressure, with 29.92 inHg equal to about 1013.2 hPa. Keeping a short list of these equivalents next to your data helps you spot a unit mix-up when a number looks off by a factor of 33.9, the pascals in 0.01 inHg.

Going from inHg back to micropascals

To convert a barometer value to micropascals, set inches of mercury as the source and micropascals as the target. One inHg is about 3.386389 × 10^9 µPa. This direction is useful when a script expects SI units and you only have a US weather report. For example, 29.92 inHg returns about 1.01321 × 10^11 µPa. The page uses the conventional definition at 0 °C, so a value measured with a mercury column at another temperature has a small correction that the page does not apply. For household purposes that correction is far below the accuracy of the instrument.

Vacuum gauges that read in inches of mercury

Automotive vacuum gauges, brake bleeders, vacuum-bagging pumps for composite work and some HVAC service tools show suction in inHg below the surrounding atmosphere. An engine at idle at sea level often shows roughly 17 to 22 inHg on such a gauge, and a hand pump for vacuum bagging may be marked up to about 25 inHg or more. A reading of 20 inHg means 20 inches of mercury below atmospheric pressure, which is 67,728 Pa, or about 6.77 × 10^10 µPa. That figure is a pressure difference, not an absolute pressure. To find the absolute pressure inside the line you subtract it from the local atmosphere, about 29.92 inHg at standard conditions, which leaves roughly 9.92 inHg. Keep gauge and absolute readings apart when you enter values here, because the converter applies the same factor to both.

What the converted number stands for

The page converts a pressure from one unit to another and nothing else. It does not correct a barometer for altitude, temperature or gravity, and it does not forecast weather. Station pressure and sea-level pressure differ, and weather reports usually give the sea-level value, so comparing a raw sensor reading with a forecast number needs that adjustment, which this page does not perform. It also does not calculate equipment ratings, installation limits or compliance. Use it to make units match, then apply the corrections that your instrument manual describes for the quantity you actually want. If you log pressure over weeks, keep the raw micropascal values in the file and convert only when you display or share a chart, so that you never lose precision to repeated rounding. Label each column with its unit in the header row as well.