SI results next to CGS references

Scientific papers and reference tables written in the centimeter-gram-second system give kinematic viscosity in stokes. A modern calculation in SI gives it in square meters per second. When a result has to be compared with a table from a handbook, a lecture course or an older paper, the two units must meet. The answer in stokes is 10,000 times the number you enter. It is useful in student labs, where textbook values in stokes are compared with measured values in SI, and in archives where a technical report of an earlier decade lists its fluid properties only in CGS. It also suits engineers who maintain legacy specifications, since many oil and process data sheets written decades ago still quote stokes and centistokes next to a newer SI column.

Why the factor is ten thousand

A stokes is defined as one square centimeter per second. A meter holds 100 centimeters, so a square meter holds 100 × 100, or 10,000, square centimeters. Seconds match on both sides. Consequently 1 m²/s equals 10,000 St, and the default of 10 m²/s converts to 100,000 St. That is unrealistically large for a fluid, so the default exists to show the factor, and a result in the hundreds of thousands of stokes should make you recheck the input. A practical conversion starts from small numbers like 10^-6 to 10^-3 m²/s and lands at hundredths to tens of stokes, which is the range in which old tables list common liquids.

Water at a hundredth of a stokes

Water near room temperature has a kinematic viscosity of about 1 × 10^-6 m²/s. The page converts 0.000001 m²/s to 0.01 St, which is the same as 1 centistoke. The figure serves as a reference: a free-flowing liquid belongs at a few hundredths of a stokes or less, and the converted number for a fluid you know to be water-like should not leave that neighborhood. A value of 0.0000003 m²/s, for hot water near boiling, comes to 0.003 St. If it does, check the exponent of the SI figure. The stokes is a large unit compared with everyday fluids, which is why the centistoke was adopted for working use and why raw stokes values for water look like tiny decimals.

Oils in stokes

A hydraulic oil at 4.6 × 10^-5 m²/s, the mid-point of ISO VG 46 at 40 °C, converts to 0.46 St. A heavy gear oil at 3.2 × 10^-4 m²/s becomes 3.2 St. These are the values older tables would print for such oils, and a reader used to centistokes would see 46 and 320. The conversion shows the relation between the CGS unit and the working unit: multiply the stokes result by 100 for centistokes. In mixed documents, a number like 0.46 can be a stokes value or a centistoke value of a very thin liquid, so the unit label is the only safeguard against a hundredfold error.

Air in stokes

Air at room temperature has a kinematic viscosity near 1.5 × 10^-5 m²/s, and the page returns 0.15 St for it. That number is close to the molecular diffusion coefficients of many gases in air, commonly around 0.1 to 0.3 cm²/s, because for gases the momentum and mass diffusion rates are similar. A physics student can use that resemblance as a check on a table. The page does not compute a diffusion coefficient, and a viscosity is not a diffusivity. It converts viscosity, and the similarity in size is a property of gases that the stokes, being literally cm²/s, makes easy to see.

Reading the unit literally

Because a stokes is a square centimeter per second, the unit can be read as an area swept per unit time, which helps with intuition. A fluid with a kinematic viscosity of 1 St spreads the effect of a moving surface over about a square centimeter each second. That picture is a loose analogy only, and no calculation here depends on it. It does explain why the unit appears in diffusion problems in chemistry and physics, where cm²/s is common. Within this page, though, the quantity is kinematic viscosity, and the converted number should be labeled as such in any table. A lab notebook entry such as 0.46 St (kinematic viscosity, hydraulic oil, 40 °C) tells the next reader everything needed to use it.

From dynamic viscosity to stokes

In CGS, dynamic viscosity is measured in poise, and kinematic viscosity equals poise divided by density in g/cm³. An oil with a dynamic viscosity of 0.04 Pa·s, which is 0.4 P, and a density of 0.87 g/cm³ has a kinematic viscosity of 0.4 / 0.87, about 0.46 St. The same oil computed in SI gives 4.598 × 10^-5 m²/s, and this page converts it to 0.4598 St, in agreement. The page has no density input, so do the division first, then use the page to move the kinematic result to stokes. The two routes agreeing is a useful self-check on a worked problem.

Centistokes or stokes

The most common error with the stokes is a factor of 100 caused by mixing it with the centistoke. A table value of 0.46 St is 46 cSt, and a reader who sees 0.46 and assumes cSt will believe the fluid is a hundred times thinner than it is. Write the unit with every number, and avoid abbreviations like S or cS in documents that will be read by people outside your field. If a report needs the centistoke figure, multiply the stokes result by 100 or use the centistokes converter for the same SI input.

Reversing the conversion

To go back, divide stokes by 10,000. A kinematic viscosity of 0.46 St returns 0.000046 m²/s. The factor is exact, since the centimeter is exactly one hundredth of a meter, and display rounding is the only source of difference between a round trip and the starting value. Reports in stokes seldom need more than two or three significant digits. State the temperature next to the value, because a viscosity without one is incomplete, and keep the SI figure in a working file so others can retrace the conversion. When a document must show both units, put the SI value first and the stokes value in parentheses, since SI is the form most current standards use.