Fuel labels and heating tables use megajoules

Heating values for fuels are normally published in megajoules per kilogram. Electricity and heat bills, heat pump brochures and battery listings use kilowatt-hours. A homeowner comparing a bag of wood pellets with an electric heater, a camper weighing a gas cylinder against a battery bank, or a student checking a lab report all end up holding a number in one unit and needing it in the other. This page changes kWh/kg into MJ/kg, and the same factor works in reverse. It handles the unit only. Whether the figure is a higher or lower heating value, or a battery capacity, comes from the document the number was taken from.

The factor of 3.6

One kilowatt-hour is 3,600,000 joules, which is 3.6 megajoules. The mass in the denominator is one kilogram in both units, so MJ/kg = kWh/kg × 3.6. The default input of 10 kWh/kg returns 36 MJ/kg. The relationship comes from the definition of the watt and the hour, and NIST SP 811 Appendix B lists the kilowatt-hour to joule conversion. In the reverse direction, 1 MJ/kg is 1/3.6, or about 0.27778, kWh/kg. That reciprocal is the number to remember when a label gives megajoules and you want a figure comparable to your electricity price per kilowatt-hour.

A bag of wood pellets as a heating job

Suppose a bag of pellets lists a heating value of 17 MJ/kg, a round figure used here for illustration. Entering 17 MJ/kg and choosing kWh/kg as the target gives about 4.7222 kWh/kg. A 15 kg bag then holds about 70.8 kWh of heat released on burning. A stove or boiler delivers only part of that to the room, since flue gas takes some away, and the efficiency is on the appliance rating plate. If a bag costs a fixed amount, dividing the price by 70.8 gives a price per kWh that you can compare with the price per kWh of electricity, with efficiencies applied to both sides.

Hydrogen and coal on the same scale

Two entries show how wide the range is. Hydrogen is quoted at about 120 MJ/kg on a lower heating value basis, which the page turns into about 33.33 kWh/kg. Coal is often listed near 24 MJ/kg, about 6.67 kWh/kg. Per kilogram, hydrogen carries five times as much energy as coal, but a kilogram of hydrogen at ordinary pressure fills a very large volume, so the per-kilogram figure alone does not show the storage problem. For that, the companion page for energy per volume is the one to use. Put the mass figure and the volume figure side by side before you judge a fuel. A reader who only sees MJ/kg may think a light fuel is automatically convenient, while one who only sees MJ/m³ may think a dense fuel is automatically compact. Each number answers one question about the fuel, and the conversion on this page keeps whichever question you started with.

Camping stoves and gas bottles

Outdoor fuel is sold by weight, which makes the mass basis natural. Propane is commonly cited near 46 MJ/kg, which is about 12.78 kWh/kg. A 450 g canister contains 0.45 kg, so roughly 5.75 kWh of chemical energy. A stove that burns it at 1 kW for boiling water would run, in theory, for about 5.75 hours, but real stoves lose heat to the air, so actual use is shorter. The value for the canister is also approximate, since camping fuel blends differ. Use the page for the unit step and take the heating value from the label or the supplier data.

Battery energy in megajoules

It is unusual to see batteries in MJ/kg, but it happens in physics courses and in comparisons with fuels. A cell at 0.2 kWh/kg, which is 200 Wh/kg, equals 0.72 MJ/kg. Set beside the pellet figure of 17 MJ/kg, the cell holds about 4 percent of the energy per kilogram, yet electric motors convert a much larger share of stored energy into motion than a small furnace or engine, so the comparison per useful kilogram is closer than the raw ratio. Keep the efficiency of each system in mind and do not read the unit conversion as a ranking of fuels. It is only a way of writing the same energy in the unit you need.

Higher and lower heating values

Heating values for fuels come in two kinds. The higher heating value counts the heat released when water vapor from combustion condenses, and the lower heating value leaves it out. For hydrogen the two differ by roughly 18 percent, and for dry wood and coal the gap is smaller but present. If you compare two fuels, both must use the same basis. A table that lists one fuel at its higher value and another at its lower value produces a misleading ratio. The converter keeps whichever value you enter, so check the footnote in the source and copy the basis alongside the converted number.

Spotting a slip in the result

Because the factor is small, mistakes are easy to miss. Multiplying by 3.6 should make the number a bit more than three times larger, so a result near 10 for an input of 10 means the wrong direction was selected. A result in the thousands for a pellet bag would mean the unit was kJ/kg or J/g by mistake. Compare against anchors you know: a 12 kWh/kg fuel should give about 43 MJ/kg, and a 5 kWh/kg fuel about 18 MJ/kg. If you are using a spreadsheet, put the formula in one cell and the unit label in the header so that later users do not apply the factor twice. Another check is to convert back: take the megajoule result, divide by 3.6, and confirm that you recover the starting kilowatt-hour figure to within rounding.

Precision and what stays outside

The factor 3.6 is exact, so the converter carries it at full precision and rounds only the displayed result, to at most 12 significant digits. Converting a rounded megajoule value back to kilowatt-hours can leave a small difference in the last digits. The page does not model combustion efficiency, moisture content, density or emissions, and it does not decide whether a fuel is suitable for any appliance. Heating values change with moisture and grade, so for a purchase or a design calculation take the number from the supplier datasheet. Treat the output as a unit conversion of that figure and nothing more.