Comparing a field under a line with the field at the wire
Overhead transmission lines present two very different field values in two different units. At ground level beneath a line, the field is measured in kilovolts per meter and amounts to a few kV/m. At the surface of the conductor itself, designers examine the gradient in kilovolts per centimeter, because corona starts when that gradient approaches the strength of air, and values in the range of 15 to 20 kV/cm are discussed in line design. To see both on the same scale, the ground-level number must be changed to kV/cm. This page divides by 100 to do exactly that, leaving the voltage prefix alone.
Why dividing by 100 is the right direction
A meter is 100 centimeters, so a given voltage drop spread over a meter is spread over 100 centimeter-long steps. The drop per centimeter is therefore one hundredth of the drop per meter. A field of 100 kV/m equals 1 kV/cm, and 5 kV/m equals 0.05 kV/cm. The formula is kV/cm = kV/m × 0.01. The relation follows from the SI definitions of the prefixes in BIPM documents and NIST SP 811, so no measured constant is involved and the conversion is exact. Per-meter numbers are bigger than per-centimeter numbers for the same field, which is the check to apply when the answer looks wrong.
The default 10 kV/m
Entering 10 kV/m returns 0.1 kV/cm. At that value the field is 100 V/cm, well below anything that causes air to break down, which needs thousands of volts per centimeter in a uniform gap. A 10 kV/m field is a plausible number near large high-voltage equipment, and it is also the kind of value reported in studies of electric fields in substations. Written as 0.1 kV/cm it looks tiny, and that shift in apparent size is the reason the choice of unit matters when you compare documents. The page exists so that a reader who sees 10 kV/m in one report and 0.1 kV/cm in another can recognize the two as identical.
Conductor surface gradient against ground-level field
Take a line whose bundle conductors have a calculated surface gradient of 16 kV/cm. In per-meter units that is 1,600 kV/m, 1.6 MV/m. Meanwhile the field at the ground is a few kV/m, for example 4 kV/m, which is 0.04 kV/cm. The page turns the second figure into a form that sits next to the first: 0.04 against 16, a ratio of 400. This large ratio is the geometric effect of distance, since the field falls off quickly away from a thin conductor. It also shows why corona, which is a surface phenomenon, is controlled by conductor diameter and bundling rather than by ground clearance.
Atmospheric fields in storms and fair weather
Atmospheric electricity is another place where per-meter units dominate. In fair weather, the vertical field near the ground is on the order of 100 to 150 V/m, which is about 0.13 kV/m. In a thunderstorm, fields at the ground can reach several kV/m or more, and fields inside the cloud are reported at higher values. Converting 0.13 kV/m gives 0.0013 kV/cm, and converting 10 kV/m, a storm-level ground field, gives 0.1 kV/cm. Neither comes close to the stress that air can support in a laboratory gap, which is why breakdown is first initiated at points and edges where the local field is greatly enhanced.
Working from voltage and distance
When you know the voltage and the distance, you can go straight to kV/cm by dividing kilovolts by centimeters, with no conversion at all. A 25 kV electrode placed 40 cm above a surface gives 0.625 kV/cm on average. This page is for the case where the source quotes kV/m. If an article gives 62.5 kV/m for the same setup, you divide by 100 to reach 0.625 kV/cm and recognize that the two descriptions agree. When one of the numbers is in millimeters or inches, convert the distance to centimeters or meters first, then use whichever of the two field units suits the document you are writing.
Field mill readings before outdoor operations
Field mills are instruments that measure the electric field at the ground, and networks of them are used where thunderstorms threaten outdoor work, such as launch sites and some airports and mines. Their output is in kV/m. Published weather rules for such sites use thresholds of about 1 kV/m, with the sign of the field mattering, so staff read numbers in kV/m all day. A site manager who also keeps laboratory notes in kV/cm can use this page to translate: 1 kV/m is 0.01 kV/cm, and a strong reading of 8 kV/m is 0.08 kV/cm. Neither figure approaches the field that makes air spark in a gap, yet a ground field of a few kV/m is a recognized sign of charge overhead, which is why the readings are logged continuously.
Spotting errors in reports
Mismatched units are a common reason why numbers in a report do not line up. A factor of 100 between two field values is a strong hint that one is per meter and the other per centimeter. A factor of 1,000 points to a voltage prefix problem such as V against kV. A factor of 10 can come from millimeters against centimeters. Use this page to test the first possibility quickly. If dividing the larger figure by 100 reproduces the smaller one, the two statements describe one field in two units, and no further investigation of the physics is needed.
Field maps near lines need modeling software
The output expresses the same field per centimeter. It does not calculate the field around a line, tell you whether corona will occur, compare a value with an exposure guideline, or confirm compliance with any standard. Field maps near real equipment depend on geometry and need the right software or a measurement. Averages from voltage over distance apply to uniform gaps only. The conversion is exact for the prefixes used, and the precision of the answer is that of the number you enter. If your source states a conductor gradient as peak and your ground-level number as RMS, the two differ by a factor of about 1.41 for a sine wave, so state which one each value is before comparing them. A gradient quoted for a specific bundle geometry applies only to that arrangement, and the ground field depends on line height and phase spacing, so the same line gives different numbers at different spans.