From the barometer to the vacuum chamber
Weather and plumbing use kilopascals, with atmospheric pressure near 101 kPa. Vacuum work uses pressures far below that, and once a chamber passes the rough vacuum range the readings fall into pascals and fractions of a pascal. Millipascals are a natural unit for high vacuum, where a gauge might read a few mPa. A lab notebook that starts from atmosphere and tracks a pump-down passes through the whole range, and putting all values in mPa gives integers for much of it. This page multiplies a kPa value by one million to give mPa.
Atmospheres and vacuum in millipascals
The default 10 kPa becomes 10,000,000 mPa. One standard atmosphere, 101.325 kPa, is 101,325,000 mPa. A pressure of 0.5 kPa is 500,000 mPa. At the high-vacuum end, 0.000001 kPa is 1 mPa, and 0.0000001 kPa is 0.1 mPa. The factor is six zeros, and since milli and kilo are six decimal places apart, a kPa figure with a single digit before the decimal point gives a seven-digit mPa figure. When you reverse the direction, divide by 1,000,000, so 250 mPa is 0.00025 kPa.
Reading a vacuum gauge in other units
Vacuum gauges are often calibrated in mbar or torr. One millibar is 100 Pa, so 1 mbar is 0.1 kPa and 100,000 mPa. A reading of 0.00001 mbar, written 1E-5 mbar, is 1 mPa or 0.000001 kPa. One torr is 133.322 Pa, so 1 millitorr is 0.133322 Pa, which is 133.322 mPa and 0.000133322 kPa. These identities let you move a number between a pump manual in mbar, a thin-film paper in Torr and a reference table in Pa. Keep the unit with each number, since the same digit can mean very different pressures across these systems.
Pump-down logs
When a chamber is pumped down, the pressure falls over many decades. A log might note 101.3 kPa at the start, 10 kPa after a minute, 0.5 kPa after several minutes and 0.001 kPa, which is 1 Pa or 1,000 mPa, after a longer time. Later steps with a turbomolecular pump bring the pressure into the range of tens of mPa and below. The pressure can drop for many minutes before it reaches a steady floor, and the floor itself tells you whether the chamber is leaking or still outgassing. Converting the entire log to mPa creates a table where the values range from 101,300,000 down to small integers, and a plot on a logarithmic axis shows the shape of the curve. The page converts values one at a time, and for a long log a spreadsheet formula does the same multiplication.
Pressure is not viscosity
The symbol mPa also appears inside mPa·s, the unit of dynamic viscosity. Water at 20 °C has a viscosity of about 1 mPa·s, and the number says nothing about a pressure of 1 mPa. The two quantities have different dimensions: one is force per area and the other is force times time per area. A technical sheet for paint, oil or syrup that gives mPa·s will not be a valid input for this page. Check that a value is a pressure before converting it, and watch for the dot or the s that marks the viscosity unit.
MPa and mPa differ by a factor of a billion
The prefix case matters. A pressure of 1 MPa is 1,000,000 Pa, which is 1,000 kPa, and 1 mPa is 0.001 Pa. A value of 5 MPa is 5,000 kPa, while 5 mPa is 0.000005 kPa. In headings and plain-text fields where the case may be lost, a hydraulic system at 21 MPa and a vacuum at 21 mPa differ by a factor of 1,000,000,000. If a value looks implausible for its setting, check whether a prefix was transcribed incorrectly. SI Brochure rules give the case for every prefix symbol, and following them avoids this mistake.
Vacuum levels and what they mean
Vacuum technology divides the range into rough, medium, high and ultra-high vacuum, with boundaries that vary slightly between sources. High vacuum sits roughly between 0.1 mPa and 100 mPa in many classifications, while ultra-high vacuum is below that. A coating or electron microscope process has its own requirement, which comes from the equipment maker or the process specification. The converter only changes the unit. It does not say whether a given pressure is sufficient for a process, and it does not account for the gas type, which affects gauge readings for many designs.
Gauge accuracy and rounding
Vacuum gauges are accurate to a fraction of a decade at best, and many are calibrated for nitrogen only. A reading of 1.0 mPa may represent a true pressure that differs by 20 percent or more, and gauge types disagree further for other gases. For this reason, report a vacuum reading to one or two significant digits. The conversion itself is exact, so the figure is only as reliable as the gauge. Treat the output as a restatement of the number you typed, and note the gauge type and gas in the log so a later reader can judge how far to trust it. Gauges drift as well, so a periodic comparison against a reference gauge belongs in the maintenance schedule.
Leak rates from pressure rise
A common leak test closes a chamber and watches the pressure rise. The leak rate equals the chamber volume times the pressure change divided by the time. A 50 L chamber whose pressure rises by 2 mPa in 100 s has a leak rate of 50 times 2 divided by 100, which is 1 mPa·L/s, or 0.001 Pa·L/s. The rise of 2 mPa is 0.000002 kPa, the form in which a gauge log in kPa might record it. Real chambers also outgas from their walls, so a rise includes more than leakage, and a longer observation or a helium test separates the two. The page supplies the pressure unit, and the test method defines how a rate is calculated and reported. Readers from different fields expect different units for the same pressure: a vacuum engineer might write 1E-5 mbar, a physicist 1 mPa, a materials scientist 7.5E-6 torr and a facility manager 0.000001 kPa, and all four are the same pressure. State the unit with every value and give an equivalent in a second unit in parentheses where the audience is mixed, so a table can be audited quickly.