Calorimeter constants in lab reports

A calorimeter has a heat capacity, often called the calorimeter constant, which tells you how much heat the vessel, stirrer, thermometer and surrounding parts absorb per degree. Modern instruments report it in joules or kilojoules per kelvin, and many textbooks and older lab manuals still use calories per degree. Students and technicians who compare an instrument printout with a worked example from a book need to switch between the two. This page converts kilojoules per kelvin to thermochemical calories per kelvin. It applies to the heat capacity of a whole object, so it is not a per-gram figure, and it keeps the interval of one kelvin, which is the same size as one degree Celsius.

How 239.0057 arises

The thermochemical calorie is defined as 4.184 J. A heat capacity of 1 kJ/K is therefore 1,000 / 4.184 = 239.005736 cal/K, which is the multiplier used by the page. The relationship comes from the definition of the calorie, which appears in NIST SP 811 as the thermochemical calorie, and from the BIPM definition of the joule and the kelvin. Because the factor is defined and not measured, it adds no uncertainty to the result. Multiplying the input in kJ/K by 239.0057 therefore gives the same quantity in cal/K to as many digits as you care to carry.

The default of 10 kJ/K

With the default of 10 kJ/K the page returns about 2,390.06 cal/K. Put another way, an object with that heat capacity absorbs 2,390 calories for every one-kelvin rise, or 2.39 kilocalories. The number is the starting point for a quick check: if you enter 1 and the result is not near 239, the menus are probably wrong. Because a calorie is a small unit and a kilojoule a larger one, the calorie figure is about 239 times the kilojoule figure, whatever the size of the input. The same ratio holds for any heat capacity entered in the page. A heat capacity of 0.5 kJ/K, small enough for a bare metal vessel, returns 119.5 cal/K, and a value of 25 kJ/K, closer to a large reaction vessel full of liquid, returns 5,975 cal/K, so the output stays in a comfortable range for most lab sheets.

A coffee-cup calorimeter with a small constant

A simple coffee-cup calorimeter has a small heat capacity compared with the water inside it. Suppose, as an illustration, a calibration gives a calorimeter constant of 0.85 kJ/K. On this page that converts to 203.15 cal/K. If a reaction raises the temperature by 3.2 K, the vessel absorbs 0.85 × 3.2 = 2.72 kJ in addition to the heat taken up by the solution, and a lab report that works in calories would list the vessel term as 650 cal. Keeping the constant in the same unit as the specific heat of the solution avoids the mix-up that often causes errors in first-year chemistry labs.

Calibrating a bomb calorimeter with benzoic acid

Bomb calorimeters are calibrated by burning a standard sample of benzoic acid, whose combustion energy is about 26.4 kJ per gram. Burning 1 g that raises the temperature by 2.5 K, an illustrative reading, gives a heat capacity of 26.4 / 2.5 = 10.56 kJ/K. Entering 10.56 on this page returns about 2,523.9 cal/K, which would be the constant in an older manual that uses calories. The certificate of the calibration material states the exact combustion energy, so use the certified value and not the rounded number here. The page only changes the unit of the resulting constant and does not evaluate the calibration itself.

Why a Celsius degree works in the denominator

A temperature interval of 1 K is the same size as an interval of 1 °C, so cal/K and cal/°C are the same unit for heat capacity. A thermometer reading changing from 21.4 °C to 24.6 °C is a rise of 3.2 °C and also 3.2 K. This is why the page lists the denominator as kelvin and still serves lab notes written in Celsius degrees. The offset between the two scales matters only for absolute temperatures, and it never appears in a difference, so you should not subtract 273.15 from anything when you use this page for a calorimeter constant. The same reasoning lets you read a lab thermometer in Celsius, record a rise of 3.2 degrees, and multiply by a constant in cal/K without any further adjustment, which keeps the arithmetic on a worksheet short and easy to audit.

Thermochemical and International Table calories

Two calories are in use. The thermochemical calorie is 4.184 J, and the International Table calorie is 4.1868 J, which is about 0.067 percent larger. This page uses the thermochemical calorie, labeled cal th. A source that quotes calories without a qualifier may mean either, and the difference of a fraction of a percent matters only in precision work. When you convert a legacy value, read the source for the definition it uses. If the source gives only the calories, the thermochemical calorie is the safer default in chemistry and nutrition, but a note about the assumption belongs in the report.

Whole-object value versus specific heat

A calorimeter constant belongs to the instrument and has no mass in its denominator. A specific heat, in cal/(g·°C), belongs to a material and must be multiplied by mass to give a heat capacity. If a book gives the heat capacity of 150 g of water as 150 cal/°C, treat it as a heat capacity and add it to the calorimeter constant to get the total in the same unit. Converting both to kJ/K or both to cal/K before adding avoids mixing units. The page converts only the whole-object quantity and has a separate converter for specific heat. As a worked case, 150 g of water contributes 150 × 1.000 = 150 cal/K and a calorimeter constant of 203 cal/K brings the total to 353 cal/K, a figure that converts to about 1.48 kJ/K on the reverse setting of this page.

Rounding and heat loss in calorimeter constants

The converter changes units and does not calibrate an instrument or predict a temperature rise. A constant in cal/K quoted to three significant figures stays at three after conversion, and it should be rounded accordingly in the final report. It does not account for heat loss to the room, stirring heat, evaporation or the heat capacity of the sample, all of which enter a real calorimetry experiment. It also provides no correction for temperature dependence of heat capacity. Use measured calibration data for the constant and use the page for the unit conversion only.