American equipment data in an SI energy balance
Thermal mass data for American buildings, boilers and storage tanks are often given as BTU per degree Fahrenheit. Energy balances in research papers, simulation tools and most of the world use joules per kelvin. This page connects the two for a heat capacity, which is the amount of heat that changes the temperature of a whole body by one degree. An engineer who imports an equipment sheet into an SI model, a student checking a textbook problem, or an energy auditor comparing a US building with a European one will use this conversion. The result goes straight into the equation Q equals C times the temperature change. Because heat capacity is additive, you can convert the parts of a system one by one and add them in joules per kelvin, which is how a building model combines walls, furniture and the air inside.
Where 1,899.100534716 comes from
The International Table BTU is defined as 1,055.05585262 joules. A temperature interval of one kelvin equals 1.8 Fahrenheit degrees, so a heat capacity of one BTU per Fahrenheit degree stores 1.8 BTU, or 1,899.100534716 joules, for each kelvin. Both inputs to the multiplication are definitions, so the factor is exact to the digits shown, and the page applies it with no approximation. The NIST conversion factor appendix, which is the source listed for this page, gives the BTU value, and the Fahrenheit relation follows from the definitions of the two temperature scales. The formula on the page reads J/K equals BTU IT/°F times 1,899.100534716.
Ten BTU/°F in joules per kelvin
Ten BTU IT/°F becomes 18,991.00534716J/K, about 18,991 J/K. Warming a body with that heat capacity by 5 kelvin takes about 94,955 joules, and by 5 degrees Fahrenheit, which is 2.778 kelvin, about 52,753 joules. The default is a small system, comparable to a few kilograms of water or a modest piece of equipment. It shows the order of magnitude you should expect from the factor: the SI number is nearly two thousand times the American one. If a result is within a few percent of the input times 1,900, the conversion is behaving.
A building frame in megajoules per kelvin
Suppose an energy model assigns an effective thermal mass of 20,000 BTU/°F to the structure and contents of a small house. That is 37,982,010.7 J/K, or about 37.98 MJ/K. In electricity terms, one kilowatt-hour is 3,600,000 joules, so 37.98 MJ/K equals 10.55 kWh for each kelvin of temperature change. Raising the whole thermal mass by 3 kelvin would take about 31.7 kWh of heat stored. The value is illustrative because real thermal mass depends on materials and on how deeply daily temperature swings penetrate. The conversion simply puts whatever value you have into the unit that SI simulation tools expect.
Smaller values: equipment and fluids
A heat exchanger shell, a pipe run or a vessel of liquid may have a heat capacity in the hundreds of BTU/°F. A value of 750 BTU/°F converts to 1,424,325.4 J/K, about 1.42 MJ/K. A value of 3.5 BTU/°F, such as a small instrument, converts to 6,646.85 J/K. Compare these with the specific heat of the material times its mass to see if they are plausible: 3.5 BTU/°F corresponds to about 3.5 pounds of water. The page does not calculate heat capacity itself, so check the number you start from before relying on the converted result. If the source lists a value per square foot of floor or per cubic foot of space, multiply by the area or volume first, because this converter expects the total for the object.
Using the result to find a temperature change
Once the heat capacity is in J/K, the temperature change of a body that absorbs heat Q is Q divided by C. If 1.5 MJ of heat enters a system with 1,424,325 J/K, the temperature rises about 1.05 K, which is 1.9 degrees Fahrenheit. The same arithmetic works in BTU directly, because 1.5 MJ is 1,422 BTU and 1,422 divided by 750 gives 1.9 degrees Fahrenheit. This cross-check is a good habit when moving between unit systems, since an inconsistency between the two routes shows a unit slip. The heat capacity is assumed constant over the range, which may not hold for large temperature swings.
Per kelvin and per degree Celsius are the same size
The denominator is a temperature interval. A kelvin and a degree Celsius are the same size, so J/K and J/°C are numerically identical, and the factor applies unchanged for a heat capacity in joules per Celsius degree. No offset is needed, because the zero points of the scales cancel when you subtract two temperatures. A Fahrenheit degree is 5/9 of a kelvin, which is exactly what the factor of 1.8 accounts for. If you treat the denominator as an absolute temperature and apply the 32-degree offset, the answer will be wrong.
Joules per kelvin back to BTU IT/°F
To convert from joules per kelvin to BTU IT/°F, choose J/K in the From list and BTU IT/°F in the To list. One J/K is 0.000526565 BTU IT/°F, and 1,000 J/K is 0.5266 BTU IT/°F. A calorimeter with a calibration of 8,500 J/K has a heat capacity of about 4.476 BTU IT/°F. Use this direction when a laboratory measurement in SI must be entered in an American design tool. The kilojoule and calorie pages on this site give the same quantity in other scales and are convenient if your data come in thousands of joules. Check the order of magnitude after reversing: a result near 0.0005 times the J/K input is right, and one near 0.5 means the unit was kJ/K.
Heat capacity and its neighbors
The page converts a property of a whole object. Specific heat capacity, in energy per mass per degree, is a different quantity, and so is volumetric heat capacity, in energy per volume per degree. If your number has mass or volume in the denominator, use the matching converter. The calculator does not estimate heat loss, phase change or the temperature dependence of heat capacity. It restates a value you provide, using the exact IT BTU definition, rounded only for display. When you copy the result into another tool, keep at least four significant figures, since rounding early and then multiplying by a large temperature change magnifies the error.