Metric data sheets and US specifications
A supplier in Europe or Asia lists a modulus in gigapascals, while the drawing you are working from calls for psi. Machine design, structural work and oilfield equipment in the United States still use pounds per square inch, and often thousands of them, written ksi. Converting a gigapascal figure gives you the number for that specification. The same job comes up when a student compares a carbon fiber listed at 230 GPa with a steel handbook that quotes 29,000 ksi. Both numbers describe stiffness, and only the units differ. The converter returns the psi value so you can set the two side by side without carrying a pocket calculator or trusting memory for a factor with six digits.
How the psi factor is defined
One psi is one pound-force per square inch. The pound-force follows from the avoirdupois pound of 0.45359237 kg and standard gravity of 9.80665 m/s², which gives 4.4482216152605 N. The inch is 25.4 mm, so a square inch is 0.00064516 m². Dividing the force by the area gives 6,894.757293168 Pa per psi, the value in NIST SP 811. One gigapascal divided by that number is 145,037.73773 psi. All inputs are definitions, so the factor is exact to the digits shown. A convenient rule is that 1 MPa is about 145.04 psi and 1 GPa is about 145,038 psi, which agrees with this page to five significant figures.
The default of 10 GPa in psi
Entering 10 GPa gives 1,450,377.3773 psi, or about 1.45 million psi. Common materials give a feel for scale. Steel at 200 GPa becomes 29,007,547.5 psi, which matches the familiar handbook value of 29 million psi for its modulus. Aluminum at 70 GPa is 10,152,641.6 psi, near 10 million psi. A plain 1 GPa gives 145,037.74 psi. Remember that these moduli are approximate, so the converted numbers carry the same uncertainty as the originals, and a handbook may round 29,007,548 to 29,000,000 for convenience. If your answer disagrees with a table by a fraction of a percent, rounding in the table is the usual cause.
Strength values in gigapascals
Stiffness is not the only property quoted in GPa. High-strength fibers and some advanced steels list tensile strength in gigapascals too. A strand rated at 3.5 GPa has a strength of 507,632 psi, which an American specification might give as 507.6 ksi. A wire of 1.77 GPa converts to 256,717 psi. Ultimate strength for ordinary structural steel is far smaller, near 0.4 to 0.5 GPa, which is 58,000 to 72,500 psi. The table looks different in each unit, but the ratios are identical. If a vendor lists a value in GPa and a requirement is in psi, converting the requirement to gigapascals is equally valid, and you can do it by choosing psi as the source unit.
Converting psi back to gigapascals
Choose psi as the source and gigapascals as the target. The page divides by 145,037.73773. A modulus of 29,000,000 psi becomes about 199.948 GPa, which is why steel is quoted as about 200 GPa in metric tables. A stress of 120,000 psi is 0.827371 GPa, or 827 MPa. A tire pressure of 35 psi is only 0.000000241 GPa, a reminder that gigapascals suit poorly for low pressures. When your psi figures are in the thousands or millions, as in structural testing and high-pressure equipment, the gigapascal scale is natural, and the round trip lets you cross-check handbooks written in different unit systems.
Gauge psi and absolute psi
Tire gauges and compressors read psig, meaning gauge pressure above ambient, while absolute pressure is quoted as psia. This converter applies only the unit factor, so it cannot tell which one you mean. At gigapascal magnitudes the distinction hardly matters, since atmospheric pressure of 14.696 psi is a rounding error beside 1.45 million psi. For low-pressure work it matters a great deal. Stress and modulus values are neither gauge nor absolute, which makes psi in that context a plain stress unit. If a source writes psi without a suffix, the surrounding text normally says whether it refers to stress or to a pressure gauge. A student working a homework problem should copy the suffix from the problem statement, since a mismatch there can cost a full point even when the arithmetic is right. The same care applies when you read a manufacturer chart, which may print psi where the test method reports stress.
Checking a requirement against a spec
A typical use is a pass or fail comparison. Suppose a US specification calls for a minimum of 150,000 psi and a supplier quotes 1.03 GPa. Converted, 1.03 GPa is 149,389 psi, which falls short, while 1.04 GPa gives 150,839 psi and passes. The comparison would be easy to get wrong by rounding the factor to 145,000 in your head, which would give 149,350 and 150,800 and is close here but drifts at larger values. A second case is a bolt or cable that a US catalog rates at 120 ksi, which is 120,000 psi or 0.827 GPa. If the metric certificate shows 0.85 GPa, the converted figure is 123,282 psi, so the lot clears the requirement by about 2.7 percent. Write both numbers on the receiving record so an inspector can follow the logic. Use the full factor when the margin is a fraction of a percent, and keep the units in view on both sides of the comparison before you accept a lot or sign a form.
Three significant figures for material data
Material data are seldom known beyond three significant figures, so a converted value like 1,450,377.3773 psi should not be quoted to ten digits. Round to the precision of the source. A modulus of 70 GPa is about 10,150,000 psi or 10.15 Msi, and a strength of 1.2 GPa is about 174,000 psi. Keep one extra digit in intermediate steps and round the final answer. A table that mixes GPa, ksi and psi should state which columns are converted from which, so a later reader can see that the metric figure is the original and the psi figure is derived from it. A shop that receives certificates in both unit systems can keep one page for each, with the conversion shown beside the value. Tables in a lab notebook benefit from the same habit: write the original value, its source, the factor and the converted result on one line.