Design tables mix GPa and MPa

Engineers and students read two kinds of numbers in the same strength-of-materials table. Elastic moduli are listed in gigapascals, and strengths, such as yield and ultimate stress, are listed in megapascals. To compute a strain from a stress, one has to divide a megapascal value by a gigapascal value, which only works after both are in one unit. This page converts GPa to MPa so that the division gives a correct strain. It is a simple factor of 1,000. The value of the page is in catching slips before they spread through a calculation. Mechanical engineering students, makers who design a 3D-printed bracket from a filament data sheet, and tradespeople who read a steel grade table all meet the two prefixes in one document, and the conversion is the first step of any stiffness or deflection check.

One step between neighbors

Giga and mega are adjacent in the SI prefix series, so MPa = GPa × 1,000. The default 10 GPa gives 10,000 MPa. An input of 0.25 GPa gives 250 MPa, 0.03 GPa gives 30 MPa and 0.2 GPa gives 200 MPa. The conversion is exact and carries no rounding, so the digits of the result are the input digits with the decimal point moved three places to the right. The pascal is one newton per square meter, as defined in the SI Brochure, and a megapascal equals one newton per square millimeter, a link that engineers use constantly. Because of that link, a 250 MPa stress is 250 newtons on each square millimeter, which is easy to picture for a bolt or a bracket. Plastics data sheets often list a modulus of 2 to 4 GPa for common 3D printing filaments, which is 2,000 to 4,000 MPa, and the same sheet lists tensile strength in the tens of megapascals.

A strain calculation that needs the conversion

Hooke law for a bar in tension says strain equals stress divided by modulus. Take steel with a modulus of about 200 GPa and a stress of 250 MPa, an illustrative value that is close to the yield strength of common structural steel grades. Converting 200 GPa gives 200,000 MPa, and the strain is 250 divided by 200,000, which is 0.00125, or 0.125 percent. A bar 2 m long stretches 2.5 mm at that strain, since 2,000 mm times 0.00125 is 2.5 mm. A DIY builder who hangs a load from a steel rod can use the same steps to see that the stretch is tiny. For a rod of 10 mm diameter, the area is about 78.5 mm², and a 10 kN load gives a stress of about 127 MPa. If the modulus is left in gigapascals and divided directly into the megapascal stress, the answer is wrong by a factor of 1,000.

Concrete, hydraulics and soil

Concrete compressive strength is stated in megapascals, with 25 to 40 MPa common for structural mixes, and its elastic modulus is a few tens of gigapascals. Hydraulic systems run at 20 to 35 MPa in many machines, and pipe pressure ratings are listed in megapascals in many countries. A design note that quotes a modulus of 30 GPa for 30 MPa concrete has two numbers that differ by 1,000 only because of the prefix. Converting 30 GPa to 30,000 MPa makes the relation visible, and an engineer can see that the strength is a thousandth of the stiffness. A homeowner who orders a concrete slab meets the same unit, since a supplier may offer a mix of 25 MPa for a garage floor and 32 MPa for a driveway, and a quote that lists a strength class by its megapascal value is easier to compare when no gigapascal figure is mixed in.

Dividing megapascals by 1,000 for gigapascals

To convert megapascals to gigapascals, choose megapascals as the source and gigapascals as the target. The page divides by 1,000. An input of 35 MPa returns 0.035 GPa, and 400 MPa returns 0.4 GPa. Results below 0.01 GPa carry leading zeros that make a table harder to read, so most strength values should stay in megapascals. Use gigapascals for moduli and for very high pressures. Matching the unit to the quantity helps readers, and this page lets you change units when a document requires a single unit for everything.

Common slips

The prefix pair is easy to confuse with mega and kilo, which would give a factor of 1,000 in the wrong place, and with milli, which is 10^-3. A table that mixes MPa and mPa has entries a billion apart. Another slip is treating a modulus as a stress limit. A modulus of 200 GPa does not say that the material carries 200 GPa, and a steel part would fail at a few hundred megapascals. A third is dropping a zero when converting 200,000 MPa back to GPa. The page prints the full number, so compare the digit count.

A 70 GPa modulus in megapascals

The factor is exact, so output digits track the input. A modulus of 70 GPa, with two significant digits, becomes 70,000 MPa, and the trailing zeros mark scale only. Material data sheets often give moduli with two or three significant digits and strengths with three. Round the result of any strain computation to the lower of the two. Handbooks give typical values and not guaranteed ones, so a modulus of 200 GPa for steel varies by a few percent between grades, and a deflection estimate built on it carries that spread. Reporting a strain of 0.001250000 from inputs of 250 MPa and 200 GPa would suggest a precision that the inputs do not have.

Typical mistakes in school lab reports

Students who compute a modulus from a tension test measure force, area and extension. The stress comes out in megapascals when the force is in newtons and the area in square millimeters, and the modulus comes out in megapascals as well, for example 200,000 MPa. The report then converts to gigapascals to compare with the textbook value of 200 GPa. This page performs the final step. If the result is off by exactly 1,000 from the textbook value, a unit slip has occurred in the area or the extension, not in the physics.

Material strength and buckling checks excluded

The conversion restates a pressure or stress value in another unit. It does not check material strength, safety factors, buckling or the suitability of any design, and it does not convert between engineering and true stress. Use the relevant code, the material data sheet and a qualified engineer for those decisions, and use this page for the arithmetic of the unit change.