British homes and two unit systems
Equipment sold in the United Kingdom today is labeled in liters per minute. Combi boilers list a hot water flow, electric showers list a maximum delivery, and caravan pumps state their output in L/min. Older manuals, plumbing books and some trade guides still describe the same appliances in imperial gallons per minute, and many people remember the old figures. Anyone replacing equipment, reading a decades-old installation note or comparing a British figure with a Commonwealth one needs both. This page converts L/min to imperial gallons per minute, and it stays on the imperial gallon throughout, which is different from the US gallon on American data sheets.
The imperial gallon and the factor
The imperial gallon is fixed at 4.54609 liters, and NIST SP 811 lists the value. Converting a flow in liters per minute to gallons per minute therefore divides by 4.54609, which is the same as multiplying by 0.219969248299. The formula on the page is imp gal/min = L/min × 0.219969248299. A quick estimate is to divide the L/min figure by 4.5, and a still quicker one is to take about 22 percent of it. Both agree with the page to within a couple of percent, and the full factor handles anything that needs more precision.
Ten liters per minute as imperial gallons
Ten liters per minute is 2.199692482990878 imperial gallons per minute, a little over two gallons. As a plumbing figure, that is the flow of a modest tap or a low flow shower head. The example tells you the rough size of the unit: a gallon is more than four liters, so the gallon number is a bit under a quarter of the liter number. If you remember that 4.5 L is about a gallon, you can check any result on this page by dividing the L/min value by 4.5 and comparing it with the figure displayed.
Combi boilers and electric showers
A combi boiler data sheet might state a hot water flow of 12 L/min at a stated temperature rise, which the page converts to 2.640 imp gal/min. An electric shower rated for 8 L/min delivers 1.760 imp gal/min. If the two are used together the demand is 20 L/min, or 4.399 imp gal/min, which will probably exceed what a combi can heat. Boiler manufacturers specify the flow for a given temperature rise because a higher flow produces cooler water, so the L/min figure alone does not settle whether a shower feels hot enough. Use the converted number for comparison with older documents. Installers also read the temperature rise printed next to the flow. A boiler that gives 12 L/min at a 35 K rise gives only about half that flow at a 70 K rise, so a higher temperature setting trades flow for heat. The converted gallons figure describes only the quantity of water, and the temperature rise decides how hot it feels.
Caravan and motorhome pumps
A caravan water pump rated at 6.5 L/min delivers 1.430 imp gal/min. Compare that with the demand of the taps and shower fitted to the van, and note that the pump flow falls as the accumulator pressure rises. A holiday traveler who finds an older campsite guide with a quoted standpipe flow in gallons per minute can use the page the other way, by swapping the units, to learn how long a 25 liter container takes to fill. The number is useful for planning how long you will stand at a tap, a small matter that fills a lot of campsite conversations. Hose pipes from a site standpipe often deliver more than the van pump can take, so the pump rating, not the site tap, limits the fill speed once the hose is connected. Filling a 40 liter onboard tank at 6.5 L/min takes about six minutes, and the same sum with gallons is harder to do in your head.
Site pumps and larger flows
A builder with a dewatering pump rated at 150 L/min has 32.995 imp gal/min at free flow. A fire service or a farm may still have a pump chart from the days when gallons were the norm, and a modern replacement is bought in liters. Converting the old chart value to L/min and the new rating to gallons gives two ways to check that the replacement is at least as large. Do the comparison at the same head, since pump flow falls as the lift rises, and keep the reserve that your old arrangement had built into it. Farms and workshops sometimes keep the original pump plate as the only record of the design flow, so photograph it, record the gallon it uses, and write the converted L/min figure beside it. The next person to replace the pump then has the number in the unit that current catalogues use.
The US gallon trap
The US liquid gallon is 3.785411784 liters, about 17 percent smaller than the imperial gallon. The same 10 L/min is 2.642 US gal/min but only 2.200 imperial gal/min, a difference of about 20 percent, since the imperial gallon is 1.2009 times the US gallon. An unlabeled table is a risk. British and Commonwealth documents written before metrication used the imperial gallon, and American ones used the US gallon. If a figure does not name its gallon, test both conversions against another number in the same document before you rely on either one.
Reading an old pump chart
Older fire service and farm pump charts quote output in imperial gallons per minute at several pressures. A pump listed at 100 gallons per minute delivers 454.6 L/min, since 100 times 4.54609 is 454.609. Use the swap of the unit menus on this page to run that direction. Then compare the figure with the L/min rating of a modern replacement at the same pressure. Charts of this type often show flow falling as pressure rises, so a single quoted figure can mislead if it was taken at low pressure. Ask for the full curve, and note the gallon that the chart uses, since some imported equipment carries US gallon charts.
What the conversion covers
Only the volume unit changes. The minute is unchanged, and the page says nothing about pressure, temperature rise, pipe size or the difference between a rated and a delivered flow. The display is rounded, and the factor is stored with twelve significant digits. Where flow is part of a safety or compliance matter, such as the supply to a fire hose reel or a hot water outlet in a care setting, work from the standard and the maker documentation, not from a converted figure. Use the page to compare units and to read old documents. Keep the converted figure next to the original in your notes, with the unit written out, so that a reader can trace how the number was produced and can repeat the conversion without guessing which gallon was meant.