A whole object, not a material
Heat capacity belongs to an object or a defined amount of matter: a calorimeter, a water tank, a boiler shell, a block of masonry, a room full of furniture. It says how much energy is needed to raise the whole thing by one degree. Calorimetry reports it in cal/K, and US building, HVAC and process engineers work in BTU per Fahrenheit degree. This page connects the two, so that a calorimeter constant or a heat capacity from a chemistry source can be used in a heating calculation in BTU. It differs from the specific heat converters on the site because no mass appears in the unit, and the result is the capacity of the whole object. It is the converter to use when you know how much heat a defined object takes per degree, not when you know a material property.
Building the factor 0.00220314823966
One cal th/K is 4.184 J/K. One BTU IT is 1,055.05585262 J and a Fahrenheit degree interval is 5/9 K, so one BTU IT/°F is 1,055.05585262 divided by 5/9, which equals 1,899.100534716 J/K. Dividing 4.184 by that number gives 0.00220314823966. The calorie value is in NIST SP 811, and the BTU value is the International Table BTU of the steam tables. The conversion shows the connection between the two systems: one BTU per degree Fahrenheit is about 453.9 calories per kelvin. Any object that holds 453.9 cal/K has a heat capacity of 1 BTU/°F.
What ten cal/K shows
The default of 10 cal th/K gives 0.0220315 BTU/°F, a tiny capacity equal to the heat capacity of 10 grams of water. It is helpful as a unit check: a gram of water is about 1 cal/K, and a pound of water is about 1 BTU/°F, so a result equal to 0.022 means about 0.022 pounds of water, or 10 grams. The same reasoning lets you sanity-check any result. A 1,000 cal/K object, equal to 1 kg of water, converts to 2.20315 BTU/°F, matching the 2.2046 lb in a kilogram of water with a small difference from the calorie definitions. The small difference between 2.2031 and 2.2046 is the 0.07 percent gap between the thermochemical calorie and the International Table units, and it is a good example of why the factor is not simply 1 over 453.6.
Calorimeter constants and water tanks
A coffee-cup calorimeter with a heat capacity of 450 cal/K converts to 0.99142 BTU/°F, close to a pound of water. A bomb calorimeter near 2,400 cal/K converts to 5.28756 BTU/°F. On a larger scale, a 300 BTU/°F hot water tank, about 36 US gallons of water at 8.34 lb per gallon, converts the other way to 136,169 cal/K. Moving between these scales helps when a laboratory heat capacity must be scaled up to an engineering model, or when a simple load estimate for a storage tank needs an equivalent in calories. Heating that tank by 40 Fahrenheit degrees takes 12,000 BTU, which is about 3.03 million thermochemical calories, since one BTU IT is about 252.2 calories.
Thermal mass in buildings
Building engineers describe thermal mass as BTU per degree Fahrenheit for a room or a wall. A concrete slab weighing 5,000 lb with a specific heat of 0.2 BTU/(lb·°F) has a heat capacity of 1,000 BTU/°F, which is 453,896 cal/K. A one degree swing in slab temperature stores or releases 1,000 BTU. The converter lets a researcher who measured a sample in the lab in cal/K compare it with such values, using the same system on both sides. These figures are illustrative, and the real specific heat of concrete varies with mix and moisture. A room containing 3,000 BTU/°F of structure and furnishings would take about 30,000 BTU to change by 10 Fahrenheit degrees, which is why a heavy building warms more slowly than a light one with the same heater.
Converting BTU/°F back to cal/K
To go the other way, choose BTU IT per Fahrenheit degree in the From menu and the calorie unit in the To menu. The page divides by 0.00220314823966, equal to multiplying by 453.896. A 100 BTU/°F object is 45,389.6 cal/K, and 1 BTU/°F is 453.896 cal/K. This is the direction for taking an HVAC or process heat capacity into a model written in metric laboratory units, such as a simulation of a calorimeter or a small thermal test rig. Rounding to one decimal is enough for a building estimate, where the structure is uncertain to ten percent or more.
Heat capacity is not specific heat
The two names are easy to mix. Specific heat is per unit mass, in cal/(g·°C) or BTU/(lb·°F). Heat capacity has no mass in the unit, in cal/K or BTU/°F. Multiplying specific heat by mass gives heat capacity. A 5 lb block with a specific heat of 0.2 BTU/(lb·°F) has a heat capacity of 1 BTU/°F. Using this page with a specific heat value would give a number that looks plausible but is dimensionally wrong, so check whether the source quantity includes a mass. The test is the unit string: if it ends in lb·°F or g·°C, it is specific heat, and if it ends only in °F or K, it is heat capacity.
The Fahrenheit interval
A Fahrenheit degree is 5/9 of a kelvin, and that ratio is part of the factor already. Never add 32 or 459.67 to the number. Those offsets apply to temperature readings, not to heat capacity, where only the size of the degree matters. A heat capacity that is 1 cal/K is the same as 0.5556 cal per Fahrenheit degree, and the BTU conversion includes this change automatically. A common error is to divide by 1.8 a second time, which makes the result 1.8 times too small.
Rounding the converted value
The multiplier is exact to the digits shown on the page. Heat capacity values from experiments rarely have more than three significant digits, so quote converted values to three or four. When the heat capacity feeds a load calculation for a building, one decimal place is usually plenty, because the surrounding assumptions are much looser than the conversion. A result of 0.991417 can be reported as 0.991.