Matching an arcsecond specification to a gon instrument

Survey instruments are advertised with an angle accuracy, and the figure is written in arcseconds in some markets and in milligon or gon in others. A total station listed at 1 arcsecond and a second one listed at 0.3 milligon belong to the same class, yet the two figures look unrelated. This page converts arcseconds to gradians, so you can read both on the same scale. You enter the arcseconds, keep gradians as the target, and get the value in gon. Multiplying by 1,000 gives milligon, the unit that most gon-based instruments display in their last digits.

Where thirty-two hundred and forty comes from

A circle holds 360 degrees, or 21,600 arcminutes, or 1,296,000 arcseconds. The same circle holds 400 gradians. Dividing 400 by 1,296,000 gives 1/3,240, which is 0.000308641975309 gon per arcsecond. Conversely, one gon is 3,240 arcseconds, 54 arcminutes or 0.9 degrees. The SI Brochure and NIST SP 811 define the gon through the radian, as π/200 rad. Since 3,240 factors into 2 cubed times 3 to the fourth times 5, a few values terminate in decimal: 324 arcseconds is exactly 0.1 gon, and 32.4 arcseconds is 0.01 gon.

What ten arcseconds comes to

With the default of 10 arcseconds, the page returns about 0.00308642 gon, which is 3.08642 milligon. Three further examples fix the scale. One arcsecond is 0.000308642 gon or 0.3086 milligon. Five arcseconds, a common instrument grade, is 0.00154321 gon or 1.543 milligon. And 3.24 arcseconds is exactly 1 milligon. Because the numbers are small, working in milligon is often more readable. A tolerance of 2 milligon corresponds to 6.48 arcseconds, and one of 0.5 milligon to 1.62 arcseconds. Memorizing the 3.24 figure speeds up any mental comparison. For example, a stated accuracy of 7 arcseconds is about 2.16 milligon, and 10 arcseconds is 3.09 milligon, so an instrument sold as 3 milligon sits close to the 10 arcsecond class. Rounding the factor to 3.24 instead of dividing by 3,240 each time changes nothing here, since 3.24 is the exact ratio.

Reading a total station data sheet

Manufacturers state angle accuracy as a standard deviation of a direction measured in two faces, following the ISO 17123-3 test procedure. An instrument with 1 arcsecond accuracy has a standard deviation of about 0.31 milligon, and a 2 arcsecond model about 0.62 milligon. At a distance of 200 meters, 1 arcsecond corresponds to a sideways displacement of 0.97 millimeters. The conversion here only changes the angle unit. It does not tell you the achieved accuracy in the field, which also depends on centering, leveling, targeting and atmospheric conditions, and which a data sheet figure does not include. Under ISO 17123-3 the quoted value comes from a standardized series of measurements in a controlled setup, so a field result in windy or hot conditions can be worse. When a project specification quotes a tolerance in gon, convert the data sheet figure to the same unit before deciding whether the instrument qualifies, and keep a margin rather than choosing an instrument whose rating equals the limit.

Back to arcseconds

The reverse conversion multiplies by 3,240. A reading of 0.0005 gon is 1.62 arcseconds, 0.001 gon is 3.24, and 0.01 gon is 32.4. Select gradians as the source and arcseconds as the target on the page. This is the direction used when a gon-based result must be reported to a client that works in degrees, minutes and seconds. For reports, convert the full angle once from gon to degrees, minutes and seconds, so rounding is applied a single time. As an example, 0.0123 gon is 39.852 arcseconds, which reads as 40 arcseconds at the precision most field books use, and 1.2346 gon is about 4,000 arcseconds, which equals 1 degree 6 minutes 40 seconds.

Gon, grad and the percent grade

The gradian is called gon in standards, grad in many calculators, and grade in some older French and German texts. None of these is the road grade, which is a slope in percent. A right angle of 100 gon is 90 degrees, so every 1 gon is 0.9 degrees, and one milligon is 3.24 arcseconds. An instrument set to the wrong unit will display angles that look plausible, because 100 gon and 90 degrees differ only by about 11 percent. Before converting, confirm which unit the source used, and write the unit next to the number. Mixing the two units on one page produces errors of about ten percent, and an arcsecond figure read as gon is off by a factor of 3,240. Gon readings entered as degrees are off by about 11 percent the other way.

Rounding in a small-angle regime

Numbers in this range have few significant digits to begin with, so rounding choices matter. A two-digit accuracy figure of 1.5 arcseconds is 0.000463 gon or 0.463 milligon, and quoting it as 0.46 milligon is enough. A theodolite display of 0.0001 gon corresponds to 0.324 arcseconds, below its stated accuracy, which is common because the display resolution is finer than the accuracy. Do not treat the last digit of a display as meaningful. When combining independent errors, add them in quadrature in one unit, and convert once at the end.

Survey grade and convergence excluded

The converter changes units. It does not estimate measurement uncertainty, test an instrument, or choose a grade for a survey. It does not convert gon bearings between grid and true north, and it does not apply any correction for convergence of meridians. Keep the original figures in your notes, so a reviewer can check the instrument settings, and cite the standard or the data sheet that gave the accuracy value.

Pairing instruments of different grades

Suppose a project specification asks for angles with a standard deviation no worse than 6 arcseconds, and the two instruments on site are a 5 arcsecond total station and an older digital theodolite rated at 2 milligon. The first is 1.54 milligon. The second is 2 × 3.24 = 6.48 arcseconds, slightly outside the limit, which the unit change makes visible at once. Converting 6 arcseconds shows the limit as 0.00185185 gon, about 1.85 milligon, so the 2 milligon instrument is over it by 0.15 milligon. This kind of screening needs one conversion per instrument and a comparison in a single unit, and the result guides which instrument takes the critical observations. The figures here are illustrative.