Where the Gal is used
The Gal, written with a capital G, is the working unit of gravimetry and strong-motion seismology. Gravity surveys for mineral exploration, oil and gas, groundwater and volcano monitoring report differences in milligals and microgals. Earthquake networks, notably in Japan, publish peak ground acceleration in Gal. A US document or a calculation done in feet per second squared has to be restated in Gal before it can be set beside those records. This page does exactly that conversion, with no intermediate unit and no approximation, and returns the figure in Gal for any acceleration you enter. Typical readers are geophysics students, survey contractors comparing instrument specifications and engineers who inherit a vibration report in customary units.
Definition and the exact factor
The Gal was introduced as a CGS unit and named in honor of Galileo, who studied falling bodies. One Gal is one centimeter per second squared, so 1 Gal equals 0.01 m/s². A foot is exactly 30.48 cm, which makes the factor between ft/s² and Gal exactly 30.48. The unit is not part of the SI, and the SI Brochure lists it among the CGS-derived units, yet geophysics still uses it, where the prefixed forms milligal and microgal are standard. The factor is exact and the result is as precise as the number you enter. Survey results are tabulated in milligals and microgals, which are one thousandth and one millionth of a Gal.
The default of 10 ft/s²
With 10 ft/s² entered, the page returns 304.8 Gal. That is an acceleration of about 0.31 g, large by gravity survey standards but small next to a strong earthquake record. Survey instruments work with changes of a few milligals across a region, which in the page would correspond to an input of around 0.0001 ft/s². Because the factor is a straight multiplication, you can scale the answer easily. A value of 1 ft/s² is 30.48 Gal, 5 ft/s² is 152.4 Gal and 0.1 ft/s² is 3.048 Gal. A gravimeter drift of one milligal corresponds to about 0.0000328 ft/s².
Gravity in Gal and how it varies
Standard gravity is 980.665 Gal. Measured values run from about 978 Gal at the equator to about 983 Gal near the poles, a spread of roughly 5 Gal, or 5,000 mGal, across the globe. Gravity also drops with height by about 0.3086 mGal per meter, the free-air gradient. A 10 ft change in elevation is 3.048 m, which shifts gravity by about 0.94 mGal, a value large enough that a gravity survey must correct for it. The tidal pull of the Moon and Sun adds variations of a few tenths of a milligal over a day. Those corrections explain why the field works in such small units. Subtracting the normal value for the latitude gives an anomaly, and anomalies of a few tens of milligals can point to a dense ore body or a salt dome.
Earthquake records in Gal
A strong-motion record reports the peak acceleration of the ground in Gal or as a fraction of g. A peak of 300 Gal equals 9.843 ft/s², and 1,000 Gal equals 32.808 ft/s², about 1.02 g. US engineering reports often list ground motion in g or in inches per second squared, so a Gal figure needs a conversion before it enters a structural calculation. Peak acceleration is only one measure of shaking, and damage depends on frequency content, duration and the structure itself. The page converts the unit for you and says nothing about how strong a quake is or how a building would respond. A peak of 500 Gal is 16.404 ft/s², or about 0.51 g, a form structural engineers write more often.
Why a ft/s² figure would appear in a Gal context
Some applied work crosses the line between the two systems. A US engineering firm may model vibration in ft/s² and need to compare it with a Gal-based sensor specification for an imported seismometer. A student might read gravity values in Gal from a geophysics text and convert them for a problem set in customary units. The tool is also useful for checking a recalled value, since 980.665 Gal should return 32.174 ft/s² when reversed. In each case the key is to have the factor exact, as it is here, and to carry the result with sensible precision. Also check whether a quoted number is a peak, an average or a root mean square, because the same event gives a different Gal value for each.
Gal versus gal and the gallon
The unit symbol Gal carries a capital G to separate it from the gallon, which uses gal in lowercase. The acceleration unit and the volume unit appear in unrelated contexts, but a search or a spreadsheet can confuse them, so check the context if a number looks odd. A spreadsheet column labeled gal in a US fuel or water record almost never refers to acceleration. The SI prefix forms are mGal for milligal, which is 10^−3 Gal or 10 µm/s², and µGal for microgal, which is 10^−8 m/s². Instruments for field gravimetry resolve fractions of a microgal under good conditions, and that is far below what a conversion factor would ever need to resolve.
Converting Gal back to feet per second squared
To convert Gal to ft/s², choose Gal as the From unit and feet per second squared as the To unit. The page divides by 30.48, so 3,048 Gal is 100 ft/s². A reading of 981 Gal becomes 32.185 ft/s², and 1,000 Gal becomes 32.808 ft/s². Quoting the result to more than the precision of the Gal figure would overstate it, so round to match. If your source gave 981 Gal, four significant figures in feet per second squared are plenty. The same page also gives m/s² and g if you need a third unit, and each of those conversions uses its own fixed factor. An acceleration of 0.5 ft/s² is 15.24 Gal.
Gravity surveys need more than a unit change
This page changes the unit of an acceleration and does nothing more. It does not reduce gravity data to a common datum, apply tide or elevation corrections, or interpret a seismic record. It does not calculate installation limits, equipment ratings, protection or compliance. For survey and engineering work, follow the method in your standard or instrument manual and use the converter only for the unit step.