What a titration result represents
In a titration, a solution of known concentration, the titrant, is added to a measured volume of a sample until the reaction between them is just complete. That point is the equivalence point. At equivalence, the moles of titrant added match the moles of sample according to the balanced equation. If you know the titrant concentration and volume, you can calculate the moles of titrant, convert to moles of sample with the coefficients, and divide by the sample volume. This page performs that calculation. It is meant for the arithmetic after the experiment, not for planning the endpoint detection. The first run is often a rough one, done quickly to find the approximate volume, and later runs add titrant dropwise near that point.
Sample concentration from titrant volume and coefficients
The calculation is sample concentration = titrant concentration × titrant volume / sample volume × sample coefficient / titrant coefficient. The defaults use 0.1 mol/L titrant, 25 mL of titrant and a 50 mL sample, with both coefficients equal to 1. The titrant supplied 0.1 × 25 = 2.5 mmol, and the sample volume of 50 mL gives 2.5 / 50 = 0.05 mol/L. Because the two volumes are divided by each other, they can be in any unit as long as both are in the same one. Milliliters work as well as liters. The coefficients do not carry units, so they are entered as plain numbers from the balanced equation.
Sulfuric acid with sodium hydroxide
Sulfuric acid reacts with sodium hydroxide in a 1 : 2 ratio, H2SO4 + 2 NaOH → Na2SO4 + 2 H2O. Suppose 25.0 mL of an acid sample needs 28.4 mL of 0.1000 mol/L sodium hydroxide. The sample is sulfuric acid with coefficient 1, and the titrant is sodium hydroxide with coefficient 2. The result is 0.1000 × 28.4 / 25.0 × 1 / 2 = 0.0568 mol/L. Forgetting the coefficient ratio would give 0.1136 mol/L, twice the right answer. The sulfuric acid is diprotic, which is the reason two hydroxide ions are consumed for each acid molecule. Whenever the acid and base react in anything other than a 1 : 1 ratio, the coefficients must be entered.
Vinegar analysis
Acetic acid reacts one-to-one with sodium hydroxide. A 10.00 mL sample of vinegar that needs 16.6 mL of 0.5000 mol/L sodium hydroxide has 0.5 × 16.6 / 10 = 0.83 mol/L of acetic acid. Multiplying by the molar mass of about 60.05 g/mol gives about 49.8 g/L, which is close to 5 percent by mass per volume, a typical label value for table vinegar. That conversion is the usual last step in a vinegar experiment. This page gives the molar concentration, and you finish the conversion to a mass concentration by multiplying by the molar mass of the analyte. Commercial vinegar is commonly sold at 5 percent acidity, so a result near 0.83 mol/L is what a correct titration should find.
A titrant with a coefficient of 1 and a sample with 2
Barium hydroxide reacts with hydrochloric acid as Ba(OH)2 + 2 HCl → BaCl2 + 2 H2O. If the barium hydroxide solution is the titrant, at 0.0500 mol/L, and 18.0 mL of it neutralize 20.0 mL of hydrochloric acid, the acid is the sample with coefficient 2 and the titrant has coefficient 1. The result is 0.0500 × 18.0 / 20.0 × 2 / 1 = 0.09 mol/L. The coefficients depend on which species you treat as the sample. Here the titrant is the base, and its coefficient is the one in the denominator. The answer is higher than the titrant concentration even though less than 20 mL was added, because each barium hydroxide formula unit neutralizes two acid molecules.
Finding the equivalence point volume
The volume entered must be at equivalence. In practice, the endpoint is detected with an indicator that changes color, or with a pH meter and a titration curve. An indicator changes color near the equivalence point only if its transition range matches the pH of that point. Phenolphthalein, which turns pink around pH 8 to 10, suits a weak acid with a strong base. The reported volume is the difference between the final and initial burette readings, read to the nearest 0.01 mL on a standard 50 mL burette. Repeat the titration until results agree within a small tolerance, and use the average. A single outlier far from the others is usually a technique problem, and it should be repeated and not averaged in.
Sources of error to watch for
Typical errors in titration work include air bubbles in the burette tip, overshooting the endpoint, an indicator that is not matched to the reaction, a titrant whose concentration has changed since it was standardized, and a sample volume measured with the wrong glassware. Sodium hydroxide solutions absorb carbon dioxide from the air, so their concentration drifts and should be standardized against a primary standard such as potassium hydrogen phthalate. A result that stays consistent across replicates but differs from expected values points to a systematic error, like the titrant concentration or the stoichiometry. Weighing the primary standard carefully and recording the burette readings to the nearest 0.01 mL keep the random part of the error small.
Dilutions and back calculations
If the sample was diluted before titration, multiply the result by the dilution factor to get the concentration of the original solution. A 10.00 mL aliquot diluted to 100.00 mL has a factor of 10. The formula also runs in reverse. If you know the sample concentration and want to know how much titrant to expect, rearrange it for the titrant volume. A quick estimate before the real titration helps you choose a burette size and a sample volume that gives a titrant volume between about 15 and 35 mL, where reading error is a small share of the volume. A titrant volume of 2 mL read with an uncertainty of 0.05 mL is 2.5 percent uncertain, while the same reading on 30 mL is under 0.2 percent.
What a titration result takes on trust
The page assumes you enter the equivalence-point volume and the coefficients of the correct balanced reaction. It does not detect an endpoint, choose an indicator, correct for side reactions or estimate uncertainty. It does not validate laboratory procedure. The sample and titrant volumes must use the same unit. The method follows the acid-base titration section of OpenStax Chemistry 2e. Handle strong acids and bases according to the safety data sheet and your institution's rules.