The weighing step before the flask

Preparing a solution of known concentration starts at the balance. You decide on a molarity and a final volume, and the question is how much solid to weigh. This page answers that question with one product of three numbers. It suits a stock solution in a teaching lab, a buffer component for a biochemistry bench or a reagent for a titration. It also helps when you scale a recipe, because the mass is proportional to both the molarity and the volume: halving the volume halves the mass, and doubling the molarity doubles it. The result is a target mass, and the actual mass on the balance will differ slightly. Record the mass you really weigh and compute the real molarity from it afterward, because the recorded value is what the solution actually contains. A solution labeled with its intended molarity but not its real one can quietly spoil a series of measurements.

From molarity and volume to grams of solute

Molarity is moles of solute per liter of solution, so moles equal molarity times volume, and mass equals moles times molar mass. In one line, mass = molarity × liters × molar mass. The defaults ask for 0.5 mol/L in 2 L using a molar mass of 58.44 g/mol, which is the molar mass of sodium chloride. That is 0.5 × 2 = 1 mol, and 1 mol × 58.44 g/mol = 58.44 g. The volume is the final volume of the solution, not the volume of solvent you start with. This distinction matters, because dissolving a solid usually changes the total volume slightly. Concentrated solutions show the effect most, since the dissolved solid takes up room of its own.

Making saline to a target concentration

A sodium chloride solution of 0.15 mol/L in 1 L requires 0.15 × 1 × 58.44 = 8.766 g of salt. This is close to the 0.9 percent mass-per-volume saline used in many biology protocols, which contains 9 g of salt per liter and is about 0.154 mol/L. Weighing 8.766 g takes a balance that reads to 0.001 g or finer. On a balance with only 0.01 g resolution, you would weigh 8.77 g and accept a molarity of about 0.1501 mol/L. Which precision is acceptable depends on the work. A rinse solution tolerates it easily, while a calibration standard for an analytical method may not.

Hydrates change the molar mass

Many solid reagents carry water in their crystals, and the molar mass must include it. Copper(II) sulfate is a good example. The anhydrous form has a molar mass of about 159.61 g/mol, and the pentahydrate, CuSO4·5H2O, about 249.68 g/mol. For 250 mL of a 0.100 mol/L solution, the anhydrous salt takes 0.100 × 0.250 × 159.61, about 3.99 g, while the pentahydrate takes 0.100 × 0.250 × 249.68, about 6.242 g. Using the wrong form gives a solution about 36 percent off. The error runs in a predictable direction: weighing the anhydrous mass when the bottle holds pentahydrate gives a solution that is too weak. The container label usually gives the formula with its water of hydration, and you should use that formula, not a generic one.

Converting volumes and small batches

The volume input is in liters, so convert milliliters by dividing by 1,000. A 250 mL flask is 0.250 L, and a 50 mL volumetric flask is 0.050 L. For a 1.0 mol/L sodium hydroxide solution in 0.5 L, with a molar mass of about 40.00 g/mol, the mass is 20.0 g. For small volumes the masses can become very small, and the weighing error becomes a larger share of the total. Preparing a larger volume and diluting part of it is often more accurate than weighing a few milligrams. A 100-fold dilution of a stock keeps the weighing error from dominating the final concentration. For example, a 1.00 mol/L stock of 100 mL needs 5.844 g of sodium chloride, and taking 1.00 mL of it into 100 mL gives 0.0100 mol/L with a much smaller relative weighing error.

Purity of the solid

The calculation assumes the solid is pure. Reagent grades differ, and a bottle labeled 98 percent holds only 98 g of the compound in each 100 g of solid. To correct for it, divide the calculated mass by the purity as a fraction. If the calculation gives 10.00 g and the reagent is 98 percent pure, weigh 10.00 / 0.98, about 10.20 g. Hygroscopic solids such as sodium hydroxide pellets absorb water from the air, so a pellet that has been sitting open weighs more than its sodium hydroxide content. Sodium hydroxide also releases heat as it dissolves, so add the pellets slowly to water and not the reverse. For these, prepare the solution approximately and then standardize it by titration against a primary standard.

Dissolving to the mark

The mass is only half of the procedure. Dissolve the solid in less solvent than the final volume, in a beaker or directly in a volumetric flask, then add solvent until the bottom of the meniscus sits on the calibration mark and mix thoroughly. Adding the solute to exactly 1 L of water would give more than 1 L of solution. Volumetric flasks are calibrated at a stated temperature, commonly 20 °C, and the solution should be near that temperature when you fill to the mark. If the dissolution warms the flask, let it cool before the final adjustment.

Molarity, molality and percent solutions

The page works in molarity. Other conventions are common. Molality counts moles per kilogram of solvent, and it does not change with temperature, which makes it useful for properties that depend on temperature. A mass-per-volume percent, such as 0.9 percent w/v, is grams of solute per 100 mL of solution, so it converts to molarity by multiplying by 10 to get g/L and then dividing by the molar mass. For 0.9 percent salt, 9 g/L divided by 58.44 g/mol is about 0.154 mol/L. Convert to molarity first if the target concentration was written in another form.

Purity and hydration a solute mass ignores

The page assumes a pure solute with the correct molar mass, complete dissolution and the stated final volume. It applies no correction for purity, hydration state, solubility, volume change or reaction with the solvent. A target that exceeds the solubility of the compound at your temperature cannot be reached, whatever the calculation says. The method follows the molarity section of OpenStax Chemistry 2e. For solutions of toxic, corrosive or reactive substances, follow the safety data sheet and your institution's procedures, since the calculator performs no hazard assessment.